PVC/NYLON 600VOLTS BUILDING WIRE
TYPE THHN/THWN
SINGLE COPPER CONDUCTOR, 90°C DRY/75°C WET
| Construction: |
| CONDUCTOR: |
SOLID OR STRANDED ANNEALED BARE COPPER.
|
| INSULATION/JACKET: |
POLYVINYL CHLORIDE (PVC) WITH NYLON JACKET.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Strands |
PVC Ins. Thickness (in.) |
Nylon Jkt Thickness (in.) |
Ampacity THWN 75°C* |
Ampacity THHN 90°C** |
Approx. O.D. (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW01124 |
1000MCM |
61 |
0.07 |
0.009 |
545 |
615 |
1.32" |
3320 |
|
| CW01123 |
750MCM |
61 |
0.07 |
0.009 |
475 |
535 |
1.15" |
2495 |
|
| CW01122 |
600MCM |
61 |
0.07 |
0.009 |
420 |
475 |
1.04" |
1998 |
|
| CW01121 |
500MCM |
37 |
0.06 |
0.008 |
380 |
430 |
.94" |
1650 |
|
| CW01120 |
400MCM |
37 |
0.06 |
0.008 |
335 |
380 |
.86" |
1344 |
|
| CW01119 |
350MCM |
37 |
0.06 |
0.008 |
310 |
350 |
.81" |
1170 |
|
| CW01118 |
300MCM |
37 |
0.06 |
0.008 |
285 |
320 |
.76" |
1015 |
|
| CW01117 |
250MCM |
37 |
0.06 |
0.008 |
255 |
290 |
.71" |
860 |
|
| CW01116 |
4/0 |
19 |
0.05 |
0.007 |
230 |
260 |
.64" |
720 |
|
| CW01115 |
3/0 |
19 |
0.05 |
0.007 |
200 |
225 |
.58" |
580 |
|
| CW01114 |
2/0 |
19 |
0.05 |
0.007 |
175 |
195 |
.53" |
464 |
|
| CW01113 |
1/0 |
19 |
0.05 |
0.007 |
150 |
170 |
.48" |
375 |
|
| CW01112 |
1 |
19 |
0.05 |
0.007 |
130 |
150 |
.44" |
302 |
|
| CW01111 |
2 |
19 |
0.04 |
0.006 |
115 |
130 |
.39" |
239 |
|
| CW01110 |
3 |
19 |
0.04 |
0.006 |
100 |
110 |
.35" |
193 |
|
| CW01109 |
4 |
19 |
0.04 |
0.006 |
85 |
95 |
.33" |
157 |
|
| CW01108 |
6 |
19 |
0.03 |
0.005 |
65 |
75 |
.26" |
99 |
|
| CW01107 |
8 |
19 |
0.03 |
0.005 |
50 |
55 |
.22" |
65 |
|
| CW01106 |
10 |
19 |
0.02 |
0.004 |
30 |
30 |
.17" |
39 |
|
| CW01105 |
12 |
19 |
0.015 |
0.004 |
20 |
20 |
.13" |
25 |
|
| CW01104 |
14 |
19 |
0.015 |
0.004 |
15 |
15 |
.11" |
17 |
|
| CW01103 |
10 |
1 |
0.02 |
0.004 |
30 |
30 |
.15" |
38 |
|
| CW01102 |
12 |
1 |
0.015 |
0.004 |
20 |
20 |
.12" |
24 |
|
| CW01101 |
14 |
1 |
0.015 |
0.004 |
15 |
15 |
.11" |
16 |
|
| Displaying 1 to 24 (of 24 products) |
Result Pages: 1 |
| * Ampacity in accordance with NEC for not more than 3 conductors at 75°C conductor temp. and 30°C ambient temp. in wet or dry locations per Table 310-16.
|
| ** Ampacity in accordance with NEC for not more than conductors at 90°C conductor temperature and 30°C ambient temperature in dry locations per Table 310-16.
|
| Note Size 14 - 10AWG ampacity values reflect adjustment for overcurrent protection per NEC 240-3.
|
| Application |
| General purpose building wire up to 600Volts with conductor temperatures of 90°C maximum in dry locations (THHN), and 75°C maximum in wet or dry locations (THWN).
|
| Standards |
| UL 83: Type THHN, THWN, Gasoline and Oil Resistant.
|
| UL 1063: Type MTW (stranded).
|
| UL 758: Type AWM (105°C).
|
| NEC Article 392: CT Use (Sizes 1/0 AWG and larger).
|
| Optional Constructions |
| Striped Conductors.
|
| THWN-2 rating: 90°C Wet or Dry.
|
|
|