LOW SMOKE TRAY CABLE - #12AWG
TYPE TC - SUNLIGHT RESISTANT, DIRECT BURIAL
XHHW-2 CONDUCTORS, LS XLPO JACKET 600VOLTS

Construction:
CONDUCTOR: 7 STRANDED BARE COPPER PER ASTM B-3.
INSULATION: THERMOSETTING FLAME-RETARDANT CROSSLINKED POLYETHYLENE (XLP) TYPE XHHW-2 PER UL 44. INSULATED CONDUCTORS RATED 90°C WET OR DRY.
CONDUCTOR IDENTIFICATION: INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532 (FORMERLY K-2).*
ASSEMBLY: CONDUCTORS ARE CABLED TOGETHER WITH A SUITABLE TAPE SEPARATOR AS NEEDED.
OVERALL JACKET: SUNLIGHT RESISTANT, FLAME RETARDANT BLACK LOW SMOKE ZERO HALOGEN CROSSLINKED POLYOLEFIN (XLPO).
 Charlotte Wire Part# ↓   Size AWG   Number of Conductors   Insulation Thickness (in.)   Jacket Thickness (in.)   Overall Diameter (in.)   Approx. Net Wt. (Lbs/Mft.)   Add to Quote Cart 
CW02921 12 2 .030" .045" .26" x .42"** 85 Request Quote For This Product 
CW02922 12 3 .030" .045" 0.44" 123 Request Quote For This Product 
CW02923 12 4 .030" .045" 0.48" 156 Request Quote For This Product 
CW02924 12 5 .030" .045" 0.54" 192 Request Quote For This Product 
CW02925 12 7 .030" .060" 0.61" 270 Request Quote For This Product 
CW02926 12 9 .030" .060" 0.71" 348 Request Quote For This Product 
CW02927 12 10 .030" .060" 0.77" 380 Request Quote For This Product 
CW02928 12 12 .030" .060" 0.80" 440 Request Quote For This Product 
CW02929 12 15 .030" .080" 0.89" 558 Request Quote For This Product 
CW02930 12 19 .030" .080" 0.96" 680 Request Quote For This Product 
CW02931 12 20 .030" .080" 1.01" 710 Request Quote For This Product 
CW02932 12 25 .030" .080" 1.12" 890 Request Quote For This Product 
CW02933 12 30 .030" .080" 1.20" 1040 Request Quote For This Product 
CW02934 12 37 .030" .080" 1.29" 1310 Request Quote For This Product 
Displaying 1 to 14 (of 14 products) Result Pages:  1 
*To Specify Method 1 Table E-1(formerly K-1) add suffix "M1" to Charlotte Wire Part Number.
**Flat Construction
Application
Suitable for control, signal, or lighting circuits rated 600Volts in power plants and heavy industrial locations where flame-resistance, stability in heat, physical durability, and excellent reliability is needed. May be used as sunlight resistant, directly buried, and wet or dry locations. Per NEC Articles 336 and 392, approved for installation in 1)raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures, 2)lighting, control, and signal circuits, 3)aerial locations where supported by a messenger wire, 4)hazardous locations per NEC Article 501 Class 1 Division 2, and 5)Class 1 circuits as permitted in NEC Article 725-21(B).
Standards
UL Standard 1277 for Type TC Cables.
Passes UL and IEEE383 70,000BTU and ICEA 210,000BTU flame test.
UL Standard 44 for Rubber Insulated Wire & Cable(XHHW2).
ICEA S-95-658/NEMA WC70 for Nonshielded 0-2KV Cables.
(Formerly ICEA S-66-524/NEMA WC70).
NEC Articles 336 &392 for Tray Cable Uses and Constructions.