LOW SMOKE TRAY CABLE - #10AWG
TYPE TC - SUNLIGHT RESISTANT, DIRECT BURIAL
XHHW-2 CONDUCTORS, LS XLPO JACKET 600VOLTS
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER PER ASTM B-3.
|
| INSULATION: |
THERMOSETTING XLP TYPE XHHW-2 PER UL 44. INSULATED CONDUCTORS RATED 90°C WET OR DRY.
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532 (FORMERLY K-2).*
|
| ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH A SUITABLE TAPE SEPARATOR AS NEEDED.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT BLACK LOW SMOKE ZERO HALOGEN CROSSLINKED POLYOLEFIN (XLPO). |
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft.) |
Add to Quote Cart |
| CW02952 |
10 |
37 |
.030" |
.080" |
1.44" |
1770 |
|
| CW02951 |
10 |
25 |
.030" |
.080" |
1.26" |
1240 |
|
| CW02950 |
10 |
19 |
.030" |
.080" |
1.08" |
975 |
|
| CW02949 |
10 |
15 |
.030" |
.080" |
1.02" |
790 |
|
| CW02948 |
10 |
12 |
.030" |
.080" |
0.94" |
650 |
|
| CW02947 |
10 |
10 |
.030" |
.080" |
0.90" |
570 |
|
| CW02946 |
10 |
9 |
.030" |
.060" |
0.80" |
460 |
|
| CW02945 |
10 |
7 |
.030" |
.060" |
0.67" |
378 |
|
| CW02944 |
10 |
5 |
.030" |
.060" |
0.62" |
283 |
|
| CW02943 |
10 |
4 |
.030" |
.060" |
0.57" |
235 |
|
| CW02942 |
10 |
3 |
.030" |
.045" |
0.49" |
170 |
|
| CW02941 |
10 |
2 |
.030" |
.045" |
.29 x .47"** |
115 |
|
| Displaying 1 to 12 (of 12 products) |
Result Pages: 1 |
| *To Specify Method 1 Table E-1(formerly K-1) add suffix "M1" to Charlotte Wire Part Number.
|
| **Flat Construction
|
| Application |
| Suitable for control, signal, or lighting circuits rated 600Volts in power plants and heavy industrial locations where flame-resistance, stability in heat, physical durability, and excellent reliability is needed. May be used as sunlight resistant, directly buried, and wet or dry locations. Per NEC Articles 336 and 392, approved for installation in 1)raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures, 2)lighting, control, and signal circuits, 3)aerial locations where supported by a messenger wire, 4)hazardous locations per NEC Article 501 Class 1 Division 2, and 5)Class 1 circuits as permitted in NEC Article 725-21(B).
|
| Standards |
| UL Standard 1277 for Type TC Cables.
|
| Passes UL and IEEE383 70,000BTU and ICEA 210,000BTU flame test.
|
| UL Standard 44 for XHHW-2 Conductors.
|
| ICEA S-95-658/NEMA WC70 for Nonshielded 0-2KV Cables.
|
| (Formerly ICEA S-66-524/NEMA WC70).
|
| NEC Articles 336 &392 for Tray Cable Uses and Constructions. |
|