VNTC TRAY CABLE -#16AWG NONSHIELDED
TYPE TC - SUNLIGHT RESISTANT,DIRECT BURIAL
TFN CONDUCTORS, PVC JACKET, 600VOLTS,UL 1277
| Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER PER ASTM B-3.
|
| INSULATION: |
POLYVINYLCHLORIDE WITH NYLON JACKET TYPE TFN PER UL 62 (GASOLINE AND OIL RESISTANT)
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532 (FORMERLY K-2).*
|
| ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH A SUITABLE TAPE SEPARATOR AS NEEDED.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT BLACK PVC PER UL 1277, WHICH PROTECTS AGAINST HEAT, FLAME, CHEMICALS, MOISTURE, AND MECHANICAL DAMAGE.
|
| Charlotte Wire Part# ↓ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) |
Nylon Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW02100 |
16 |
2 |
0.015 |
0.004 |
0.045 |
.23" x .30"** |
45 |
|
| CW02101 |
16 |
3 |
0.015 |
0.004 |
0.045 |
.32" |
58 |
|
| CW02102 |
16 |
4 |
0.015 |
0.004 |
0.045 |
.34" |
72 |
|
| CW02103 |
16 |
5 |
0.015 |
0.004 |
0.045 |
.37" |
86 |
|
| CW02104 |
16 |
6 |
0.015 |
0.004 |
0.045 |
.40" |
100 |
|
| CW02105 |
16 |
7 |
0.015 |
0.004 |
0.045 |
.40" |
111 |
|
| CW02106 |
16 |
8 |
0.015 |
0.004 |
0.045 |
.43" |
125 |
|
| CW02107 |
16 |
9 |
0.015 |
0.004 |
0.045 |
.46" |
139 |
|
| CW02108 |
16 |
10 |
0.015 |
0.004 |
0.045 |
.50" |
154 |
|
| CW02109 |
16 |
12 |
0.015 |
0.004 |
0.045 |
.52" |
179 |
|
| CW02110 |
16 |
15 |
0.015 |
0.004 |
0.06 |
.59" |
232 |
|
| CW02111 |
16 |
16 |
0.015 |
0.004 |
0.06 |
.61" |
244 |
|
| CW02112 |
16 |
19 |
0.015 |
0.004 |
0.06 |
.63" |
283 |
|
| CW02113 |
16 |
20 |
0.015 |
0.004 |
0.06 |
.65" |
297 |
|
| CW02114 |
16 |
25 |
0.015 |
0.004 |
0.06 |
.73" |
363 |
|
| CW02115 |
16 |
30 |
0.015 |
0.004 |
0.06 |
.78" |
427 |
|
| CW02116 |
16 |
37 |
0.015 |
0.004 |
0.08 |
.88" |
545 |
|
| CW02117 |
16 |
50 |
0.015 |
0.004 |
0.08 |
.99" |
712 |
|
| Displaying 1 to 18 (of 18 products) |
Result Pages: 1 |
| *To specify Method 1 Table E-1(formerly K-1), add suffix "M1" to Charlotte Wire Part Number.
|
| ** Flat Construction
|
| Application |
| Control, Signal, or Lighting circuits rated 600Volts.
|
| May be used as sunlight resistant, directly buried, and wet or dry locations.
|
| Per NEC Articles 336 and 392, approved for installation in
|
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures,
|
| 2) lighting, control, and signal circuits
|
| 3) aerial locations where supported by a messenger wire
|
| 4) hazardous locations per Art.501 Class 1 Division 2,
|
| 5) Class 1 circuits as permitted in Article 725-21(B).
|
| Standards |
| UL Standard 1277 for Type TC Cables
|
| Passes UL and IEEE383 70,000BTU Flame Test.
|
| UL Standard 62 for TFN Conductors
|
| NEC Articles 336 and 392 for Tray Cable uses and constructions.
|
|
|