VNTC TRAY CABLE - #16AWG SHIELDED
TYPE TC - SUNLIGHT RESISTANT,DIRECT BURIAL
TFN CONDUCTORS, PVC JACKET, 600VOLTS,UL 1277

Construction:
CONDUCTOR: 7 STRANDED BARE COPPER PER ASTM B-3.
INSULATION: POLYVINYLCHLORIDE WITH NYLON JACKET TYPE TFN PER UL 62 (GASOLINE AND OIL RESISTANT)
CONDUCTOR IDENTIFICATION: INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE K-2 OF ICEA S-73-532 (FORMERLY K-2).*
ASSEMBLY: CONDUCTORS ARE TWISTED TOGETHER WITH ALUMINUM/MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE TO PROVIDE 100% SHIELDING COVERAGE.
OVERALL JACKET: SUNLIGHT RESISTANT, FLAME RETARDANT, BLACK PVC PER UL 1277, WHICH PROTECTS AGAINST HEAT, FLAME, CHEMICALS, MOISTURE, AND MECHANICAL DAMAGE.
 Charlotte Wire Part#* ↓   Size AWG   Number of Conductors   Insulation Thickness (in.)   Nylon Thickness (in.)   Jacket Thickness (in.)   Overall Diameter (in.)   Approx. Net Wt. (Lbs/Mft)   Add to Quote Cart 
CW02151 16 2 0.015 0.004 0.045 .31" 45 Request Quote For This Product 
CW02152 16 3 0.015 0.004 0.045 .32" 59 Request Quote For This Product 
CW02153 16 4 0.015 0.004 0.045 .34" 73 Request Quote For This Product 
CW02154 16 5 0.015 0.004 0.045 .37" 87 Request Quote For This Product 
CW02155 16 6 0.015 0.004 0.045 .40" 100 Request Quote For This Product 
CW02156 16 7 0.015 0.004 0.045 .40" 112 Request Quote For This Product 
CW02157 16 8 0.015 0.004 0.045 .43" 126 Request Quote For This Product 
CW02158 16 10 0.015 0.004 0.045 .50" 154 Request Quote For This Product 
CW02159 16 12 0.015 0.004 0.045 .52" 180 Request Quote For This Product 
CW02160 16 19 0.015 0.004 0.06 .63" 285 Request Quote For This Product 
CW02161 16 25 0.015 0.004 0.06 .73" 365 Request Quote For This Product 
CW02162 16 37 0.015 0.004 0.08 .88" 548 Request Quote For This Product 
CW02163 16 9 0.015 0.004 0.045 .48" 139 Request Quote For This Product 
Displaying 1 to 13 (of 13 products) Result Pages:  1 
* To specify Method 1 Table E-1(formerly K-1), add suffix "M1" to Charlotte Wire Part Number.
Application
Control, Instrumentation, Signal or Lighting circuits rated 600Volts or less where circuit protection from ambient electrical interference is needed.
May be used as sunlight resistant, directly buried, and wet or dry locations.
Per NEC Articles 336 and 392, approved for installation in
1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures,
2) lighting, control, and signal circuits
3) aerial locations where supported by a messenger wire
4) hazardous locations per Art.501 Class 1 Division 2, and
5) Class 1 circuits as permitted in Article 725-21(B).
Standards
UL Standard 1277 for Type TC Cables
Passes UL and IEEE383 70,000BTU Flame Test.
UL Standard 62 for TFN Conductors
NEC Articles 336 and 392 for Tray Cable uses and constructions.