VNTC TRAY CABLE - #12AWG NONSHIELDED
TYPE TC - SUNLIGHT RESISTANT,DIRECT BURIAL
THHN CONDUCTORS, PVC JACKET, 600VOLTS, UL 1277
| Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER PER ASTM B-3.
|
| INSULATION: |
POLYVINYLCHLORIDE WITH NYLON JACKET TYPE THHN/THWN PER UL 83 (GASOLINE AND OIL RESISTANT)
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532 (FORMERLY K-2).*
|
| ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH A SUITABLE TAPE SEPARATOR AS NEEDED.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT BLACK PVC PER UL1277, WHICH PROTECTS AGAINST HEAT, FLAME, CHEMICALS, MOISTURE, AND MECHANICAL DAMAGE.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) |
Nylon Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW02315 |
12 |
37 |
0.015 |
0.004 |
0.08 |
1.10" |
1130 |
|
| CW02314 |
12 |
30 |
0.015 |
0.004 |
0.08 |
1.02" |
930 |
|
| CW02313 |
12 |
25 |
0.015 |
0.004 |
0.08 |
.92" |
760 |
|
| CW02312 |
12 |
20 |
0.015 |
0.004 |
0.06 |
.81" |
613 |
|
| CW02311 |
12 |
19 |
0.015 |
0.004 |
0.06 |
.79" |
584 |
|
| CW02310 |
12 |
16 |
0.015 |
0.004 |
0.06 |
.76" |
485 |
|
| CW02309 |
12 |
15 |
0.015 |
0.004 |
0.06 |
.73" |
470 |
|
| CW02308 |
12 |
12 |
0.015 |
0.004 |
0.06 |
.67" |
386 |
|
| CW02307 |
12 |
10 |
0.015 |
0.004 |
0.06 |
.65" |
330 |
|
| CW02306 |
12 |
9 |
0.015 |
0.004 |
0.06 |
.61" |
290 |
|
| CW02305 |
12 |
7 |
0.015 |
0.004 |
0.045 |
.49" |
223 |
|
| CW02304 |
12 |
6 |
0.015 |
0.004 |
0.045 |
.49" |
196 |
|
| CW02303 |
12 |
5 |
0.015 |
0.004 |
0.045 |
.45" |
166 |
|
| CW02302 |
12 |
4 |
0.015 |
0.004 |
0.045 |
.42" |
137 |
|
| CW02301 |
12 |
3 |
0.015 |
0.004 |
0.045 |
.38" |
108 |
|
| CW02300 |
12 |
2 |
0.015 |
0.004 |
0.045 |
.23" x .36"** |
79 |
|
| Displaying 1 to 16 (of 16 products) |
Result Pages: 1 |
| *To Specify Method 1 Table E-1(formerly K-1), add suffix "M1" to Charlotte Wire Part Number.
|
| ** Flat Construction
|
| Application |
| Control, Power, Signal, or Lighting circuits rated 600Volts.
|
| May be used as sunlight resistant, directly buried, and wet or dry locations.
|
| Per NEC Articles 336 and 392, approved for installation in
|
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures,
|
| 2) lighting, power, control, and signal circuits,
|
| 3) aerial locations where supported by a messenger wire
|
| 4) hazardous locations per Art.501 Class 1 Division 2, and
|
| 5) Class 1 circuits as permitted in Article 725-21(B).
|
| Standards |
| UL Standard 1277 for Type TC Cables.
|
| Passes UL and IEEE383 70,000BTU Flame Test.
|
| UL Standard 83 for THHN Conductors.
|
| NEC Articles 336 and 392 for Tray Cable uses and constructions.
|
|
|