VNTC TRAY CABLE-#12 & #10AWG SHIELDED
TYPE TC - SUNLIGHT RESISTANT,DIRECT BURIAL
THHN CONDUCTORS, PVC JACKET, 600VOLTS, UL 1277
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER PER ASTM B-3.
|
| INSULATION: |
POLYVINYLCHLORIDE WITH NYLON JACKET TYPE THHN/THWN PER UL 83 (GASOLINE AND OIL RESISTANT)
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532 (FORMERLY K-2).*
|
| ASSEMBLY: |
CONDUCTORS ARE TWISTED TOGETHER WITH ALUMINUM/MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE TO PROVIDE 100% SHIELDING COVERAGE.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT BLACK PVC PER UL 1277, WHICH PROTECTS AGAINST HEAT, FLAME, CHEMICALS, MOISTURE, AND MECHANICAL DAMAGE.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) |
Nylon Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW02368 |
10 |
12 |
0.02 |
0.004 |
0.08 |
.88" |
590 |
|
| CW02365 |
10 |
7 |
0.02 |
0.004 |
0.045 |
.63" |
360 |
|
| CW02363 |
10 |
5 |
0.02 |
0.004 |
0.045 |
.58" |
267 |
|
| CW02362 |
10 |
4 |
0.02 |
0.004 |
0.045 |
.50" |
201 |
|
| CW02361 |
10 |
3 |
0.02 |
0.004 |
0.045 |
.46" |
157 |
|
| CW02360 |
10 |
2 |
0.02 |
0.004 |
0.045 |
.43" |
115 |
|
| CW02359 |
12 |
37 |
0.015 |
0.004 |
0.08 |
1.10" |
1135 |
|
| CW02358 |
12 |
19 |
0.015 |
0.004 |
0.06 |
.79" |
587 |
|
| CW02357 |
12 |
12 |
0.015 |
0.004 |
0.06 |
.67" |
389 |
|
| CW02356 |
12 |
9 |
0.015 |
0.004 |
0.06 |
.61" |
292 |
|
| CW02355 |
12 |
7 |
0.015 |
0.004 |
0.045 |
.49" |
225 |
|
| CW02354 |
12 |
5 |
0.015 |
0.004 |
0.045 |
.45" |
169 |
|
| CW02353 |
12 |
4 |
0.015 |
0.004 |
0.045 |
.42" |
139 |
|
| CW02352 |
12 |
3 |
0.015 |
0.004 |
0.045 |
.38" |
110 |
|
| CW02351 |
12 |
2 |
0.015 |
0.004 |
0.045 |
.36" |
81 |
|
| Displaying 1 to 15 (of 15 products) |
Result Pages: 1 |
| *To specify Method 1 Table E-1(formerly K-1), add suffix "M1" to Charlotte Wire Part Number.
|
| Application |
| Control, Instrumentation, signal, or Lighting circuits rated 600Volts or less where circuit protection from ambient electrical interference is needed.
|
| May be used as sunlight resistant, directly buried, and wet or dry locations.
|
| Per NEC Articles 336 and 392, approved for installation in
|
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures,
|
| 2) lighting, control, and signal circuits
|
| 3) aerial locations where supported by a messenger wire
|
| 4) hazardous locations per Art.501 Class 1 Division 2, and
|
| 5) Class 1 circuits as permitted in Article 725-21(B).
|
| Standards |
| UL Standard 1277 for Type TC Cables.
|
| Passes UL and IEEE383 70,000BTU Flame Test.
|
| UL Standard 83 for THHN Conductors.
|
| NEC Articles 336 and 392 for Tray Cable uses and constructions.
|
|