VNTC TRAY CABLE- 3 CONDUCTOR W/GROUND
TYPE TC - SUNLIGHT RESISTANT, DIRECT BURIAL
THHN CONDUCTORS, PVC JACKET, 600VOLTS, UL 1277
| Construction: |
| CONDUCTOR: |
CLASS B STRANDED BARE COPPER PER ASTM B-3.
|
| INSULATION: |
POLYVINYLCHLORIDE WITH NYLON JACKET TYPE THHN/THWN PER UL 83 (GASOLINE AND OIL RESISTANT)
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS COLOR CODED PER ICEA METHOD 4 (BLACK CONDUCTORS WITH PRINTED NUMBERS) ON #8AWG AND LARGER.
|
| SIZES 14 THROUGH 10 COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532 (FORMERLY K-2), WHICH IS BLACK-RED-BLUE.
|
| ASSEMBLY: |
CONDUCTORS CABLED TOGETHER WITH A STRANDED COPPER GROUND WIRE IN ONE OF THE INTERSTICES, SUITABLE FILLERS FOR ROUNDNESS WHERE NEEDED, AND CABLE TAPE.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT BLACK PVC PER UL 1277, WHICH PROTECTS AGAINST HEAT, FLAME, CHEMICALS, MOISTURE, AND MECHANICAL DAMAGE.
|
| Charlotte Wire Part# ↑ |
3 Cond'r Cable Size |
Number of Strands |
Insulation Thickness (in.) PVC |
Insulation Thickness (in.) Nylon |
Jacket Thickness (in.) |
Ground Wire Size (AWG) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW02414 |
1000MCM |
61 |
0.07 |
0.009 |
0.14 |
1/0 |
3.17" |
12940 |
|
| CW02413 |
750MCM |
61 |
0.07 |
0.009 |
0.11 |
1 |
2.83" |
9050 |
|
| CW02412 |
500MCM |
37 |
0.06 |
0.008 |
0.11 |
2 |
2.26" |
6100 |
|
| CW02411 |
350MCM |
37 |
0.06 |
0.008 |
0.11 |
3 |
1.97" |
4250 |
|
| CW02410 |
250MCM |
37 |
0.06 |
0.008 |
0.11 |
4 |
1.76" |
3190 |
|
| CW02409 |
4/0 |
19 |
0.05 |
0.007 |
0.11 |
4 |
1.55" |
2650 |
|
| CW02408 |
3/0 |
19 |
0.05 |
0.007 |
0.08 |
4 |
1.43" |
2190 |
|
| CW02407 |
2/0 |
19 |
0.05 |
0.007 |
0.08 |
6 |
1.32" |
1790 |
|
| CW02406 |
1/0 |
19 |
0.05 |
0.007 |
0.08 |
6 |
1.22" |
1480 |
|
| CW02405 |
1 |
19 |
0.05 |
0.007 |
0.08 |
6 |
1.15" |
1255 |
|
| CW02404 |
2 |
7 |
0.04 |
0.006 |
0.08 |
6 |
1.01" |
975 |
|
| CW02403 |
4 |
7 |
0.04 |
0.006 |
0.08 |
8 |
.88" |
662 |
|
| CW02402 |
6 |
7 |
0.03 |
0.005 |
0.06 |
8 |
.69" |
440 |
|
| CW02401 |
8 |
7 |
0.03 |
0.005 |
0.06 |
10 |
.62" |
300 |
|
| CW02400 |
10 |
7 |
0.015 |
0.004 |
0.045 |
10 |
.48" |
195 |
|
| CW02399 |
12 |
7 |
0.015 |
0.004 |
0.045 |
12 |
.40" |
132 |
|
| CW02398 |
14 |
7 |
0.015 |
0.004 |
0.045 |
14 |
.36" |
93 |
|
| Displaying 1 to 17 (of 17 products) |
Result Pages: 1 |
| Application |
| Power circuits rated 600Volts, 90°C in dry locations and 75°C in wet locations.
|
| Per NEC Articles 338 and 392, approved for installation in
|
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures,
|
| 2) aerial locations where supported by a messenger wire,
|
| 3) hazardous locations per Art.501 Class 1 Division 2.
|
| Standards |
| UL Standard 1277 for Type TC Cables.
|
| Passes UL and IEEE383 70,000BTU Flame Test.
|
| UL Standard 83 for THHN Conductors.
|
| NEC Articles 336 and 392 for Tray Cable uses and constructions.
|
|
|