Pendant AND REELING CONTROL CABLE
TYPE TC #18AWG - SMALL DIAMETER
90°C, 600VOLTS, UL 1277 SUNLIGHT RESISTANT
| Construction: |
| CONDUCTOR: |
16 STRANDED SOFT DRAWN BARE COPPER.
|
| INSULATION: |
FLAME-RETARDANT POLYMER WITH NYLON JACKET.
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532. (FORMERLY K-2).
|
| ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH SUITABLE FILLERS WHERE NEEDED AND A MYLAR TAPE SEPARATOR IS APPLIED OVER THE CONDUCTOR ASSEMBLY.
|
| OVERALL JACKET: |
HEAVY DUTY THERMOSETTING BLACK NEOPRENE PER UL 1277, WHICH PROTECTS AGAINST FLAME, CHEMICALS, OIL, MOISTURE, SUNLIGHT, AND ABRASION.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) Polymer |
Insulation Thickness (in.) Nylon |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03264 |
18 |
37 |
0.015 |
0.004 |
0.06 |
.77" |
400 |
|
| CW03263 |
18 |
30 |
0.015 |
0.004 |
0.06 |
.71" |
330 |
|
| CW03262 |
18 |
24 |
0.015 |
0.004 |
0.06 |
.68" |
280 |
|
| CW03261 |
18 |
21 |
0.015 |
0.004 |
0.06 |
.61" |
270 |
|
| CW03260 |
18 |
19 |
0.015 |
0.004 |
0.06 |
.58" |
240 |
|
| CW03259 |
18 |
16 |
0.015 |
0.004 |
0.045 |
.52" |
185 |
|
| CW03258 |
18 |
12 |
0.015 |
0.004 |
0.045 |
.47" |
145 |
|
| CW03257 |
18 |
10 |
0.015 |
0.004 |
0.045 |
.46" |
130 |
|
| CW03256 |
18 |
9 |
0.015 |
0.004 |
0.045 |
.46" |
120 |
|
| CW03255 |
18 |
8 |
0.015 |
0.004 |
0.045 |
.43" |
115 |
|
| CW03254 |
18 |
7 |
0.015 |
0.004 |
0.045 |
.37" |
100 |
|
| CW03253 |
18 |
6 |
0.015 |
0.004 |
0.045 |
.37" |
90 |
|
| CW03252 |
18 |
5 |
0.015 |
0.004 |
0.045 |
.34" |
80 |
|
| CW03251 |
18 |
3 |
0.015 |
0.004 |
0.045 |
.30" |
60 |
|
| CW03250 |
18 |
2 |
0.015 |
0.004 |
0.045 |
.28" |
52 |
|
| Displaying 1 to 15 (of 15 products) |
Result Pages: 1 |
| Application |
| Designed for use in flexing and reeling applications
|
| where mechanical toughness and small diameters are needed,
|
| such as cranes, hoists, pendant stations, platforms, and other
|
| moving industrial equipment.
|
| May be used in indoor and outdoor
|
| applications, including sunlight resistant, direct burial, and
|
| wet or dry locations.
|
| Per NEC Articles 336 and 392, approved for installation in
|
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar Structures,
|
| 2) hazardous locations per Article 501 Class 1 Division 2, and
|
| 3) Class 1 circuits as permitted in Article 725-21(B).
|
| Standards |
| UL Standard 1277 for Type TC Cables.
|
| Passes UL and IEEE383 70,000 BTU Flame Test.
|
| NEC Articles 336 and 392 for Tray Cable uses and constructions.
|
|
|