PENDANT AND REELING CONTROL CABLE
TYPE TC #16AWG - SMALL DIAMETER
90°C, 600VOLTS, UL 1277 SUNLIGHT RESISTANT
| Construction: |
| CONDUCTOR: |
19 STRANDED SOFT DRAWN BARE COPPER.
|
| INSULATION: |
FLAME-RETARDANT POLYMER WITH NYLON JACKET.
|
| CONDUCTOR IDENTIFICATION: |
INSULATED CONDUCTORS ARE COLOR CODED PER ICEA METHOD 1 TABLE E-2 OF ICEA S-73-532. (FORMERLY K-2).
|
| ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH SUITABLE FILLERS WHERE NEEDED AND A MYLAR TAPE SEPARATOR IS APPLIED OVER THE CONDUCTOR ASSEMBLY.
|
| OVERALL JACKET: |
HEAVY DUTY THERMOSETTING BLACK NEOPRENE PER UL 1277, WHICH PROTECTS AGAINST FLAME, CHEMICALS, OIL, MOISTURE, SUNLIGHT, AND ABRASION.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) Polymer |
Insulation Thickness (in.) Nylon |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03287 |
16 |
60 |
0.015 |
0.004 |
0.06 |
1.06" |
870 |
|
| CW03286 |
16 |
37 |
0.015 |
0.004 |
0.06 |
.87" |
530 |
|
| CW03285 |
16 |
30 |
0.015 |
0.004 |
0.06 |
.78" |
450 |
|
| CW03284 |
16 |
24 |
0.015 |
0.004 |
0.06 |
.73" |
375 |
|
| CW03283 |
16 |
21 |
0.015 |
0.004 |
0.06 |
.66" |
340 |
|
| CW03282 |
16 |
20 |
0.015 |
0.004 |
0.06 |
.65" |
335 |
|
| CW03281 |
16 |
19 |
0.015 |
0.004 |
0.06 |
.63" |
310 |
|
| CW03280 |
16 |
16 |
0.015 |
0.004 |
0.06 |
.61" |
265 |
|
| CW03279 |
16 |
12 |
0.015 |
0.004 |
0.045 |
.52" |
195 |
|
| CW03278 |
16 |
10 |
0.015 |
0.004 |
0.045 |
.51" |
170 |
|
| CW03277 |
16 |
9 |
0.015 |
0.004 |
0.045 |
.51" |
165 |
|
| CW03276 |
16 |
8 |
0.015 |
0.004 |
0.045 |
.46" |
145 |
|
| CW03275 |
16 |
7 |
0.015 |
0.004 |
0.045 |
.40" |
120 |
|
| CW03274 |
16 |
6 |
0.015 |
0.004 |
0.045 |
.40" |
115 |
|
| CW03273 |
16 |
5 |
0.015 |
0.004 |
0.045 |
.37" |
100 |
|
| CW03272 |
16 |
4 |
0.015 |
0.004 |
0.045 |
.35" |
85 |
|
| CW03271 |
16 |
3 |
0.015 |
0.004 |
0.045 |
.31" |
70 |
|
| CW03270 |
16 |
2 |
0.015 |
0.004 |
0.045 |
.30" |
55 |
|
| Displaying 1 to 18 (of 18 products) |
Result Pages: 1 |
| Application |
| Designed for use in flexing and reeling applications where mechanical toughness and small diameters are needed, such as cranes, hoists, pendant stations, platforms, and other moving industrial equipment.
|
| May be used in indoor and outdoor applications, including sunlight resistant, direct burial, and wet or dry locations.
|
| Per NEC Articles 336 and 392, approved for installation in
|
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures,
|
| 2) hazardous locations per Article 501 Class 1 Division 2, and
|
| 3) Class 1 circuits as permitted in Article 725-21(B).
|
| Standards |
| UL Standard 1277 for Type TC Cables.
|
| Passes UL and IEEE383 70,000 BTU Flame Test.
|
| NEC Articles 336 and 392 for Tray Cable uses and constructions.
|
|
|