INSTRUMENT CABLE - #20AWG
SHIELDED PAIRS OR TRIADS WITH OVERALL SHIELD
TYPE PLTC, 105°C, 300VOLTS
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER. |
| INSULATION: |
FLAME RETARDANT PVC. |
| COLOR CODE: |
PAIRS ARE CODED BLACK AND WHITE; TRIADS ARE CODED BLACK, WHITE, AND RED. |
| ONE CONDUCTOR IN EACH PAIR OR TRIAD IS ALSO NUMBERED FOR EASE OF IDENTIFICATION. |
| PAIRS/TRIADS: |
INSULATED CONDUCTORS TWISTED INTO PAIRS OR TRIADS WITH AN APPROXIMATE 2" LAY OF TWIST TO REDUCE CROSSTALK. |
| TWISTED PAIRS OR TRIADS INDIVIDUALLY SHIELDED WITH ALUMINUM/MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE. |
| OVERALL SHIELD: |
SHIELDED PAIRS CABLED TOGETHER WITH OVERALL ALUMINUM MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE TO PROVIDE 100% SHIELDING COVERAGE. |
| RIP CORD |
NYLON RIPCORD APPLIED UNDER JACKET TO HELP STRIP JACKET. |
| JACKET: |
SUNLIGHT AND MOISTURE RESISTANT, FLAME RETARDANT BLACK PVC. |
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Pairs |
Number of Triads |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW05141 |
20 |
6 |
- |
0.015 |
0.05 |
.50" |
140 |
|
| CW05140 |
20 |
- |
24 |
0.015 |
0.07 |
1.04" |
602 |
|
| CW05139 |
20 |
- |
16 |
0.015 |
0.06 |
.85" |
400 |
|
| CW05138 |
20 |
- |
12 |
0.015 |
0.06 |
.76" |
310 |
|
| CW05137 |
20 |
- |
8 |
0.015 |
0.05 |
.63" |
216 |
|
| CW05136 |
20 |
- |
4 |
0.015 |
0.05 |
.48" |
130 |
|
| CW05135 |
20 |
- |
2 |
0.015 |
0.05 |
.41" |
80 |
|
| CW05134 |
20 |
50 |
- |
0.015 |
0.07 |
1.28" |
890 |
|
| CW05133 |
20 |
36 |
- |
0.015 |
0.07 |
1.07" |
655 |
|
| CW05132 |
20 |
24 |
- |
0.015 |
0.07 |
.94" |
460 |
|
| CW05131 |
20 |
20 |
- |
0.015 |
0.06 |
.82" |
377 |
|
| CW05130 |
20 |
16 |
- |
0.015 |
0.06 |
.75" |
310 |
|
| CW05129 |
20 |
12 |
- |
0.015 |
0.06 |
.67" |
250 |
|
| CW05128 |
20 |
8 |
- |
0.015 |
0.05 |
.54" |
169 |
|
| CW05127 |
20 |
4 |
- |
0.015 |
0.05 |
.43" |
101 |
|
| CW05126 |
20 |
2 |
- |
0.015 |
0.04 |
.36" |
67 |
|
| Displaying 1 to 16 (of 16 products) |
Result Pages: 1 |
| Application |
| Instrumentation and Control Circuits rated 300volts or less. |
| Per NEC Article 725, approved for installation in |
| 1) Cable trays indoors and outdoors, |
| 2) raceways, |
| 3) supported by a messenger wire, |
| 4) hazardous locations per NEC Art.501-4(b) Class 1 Division 2, |
| 5) Cable trays in hazardous locations per NEC Art.502-4(b) Class 2 Division 2, |
| 6) CL2 and CL3 applications. |
| Standards |
| UL Subject 13. |
| Passes UL and IEEE383 70,000BTU Flame Test. |
| NEC Article 725 Class 2 and Class 3 Circuits. |
|