INSTRUMENT CABLE - #18AWG
SHIELDED PAIRS OR TRIADS WITH OVERALL SHIELD
TYPE PLTC, 105°C, 300VOLTS
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER. |
| INSULATION: |
FLAME RETARDANT PVC. |
| COLOR CODE: |
PAIRS ARE CODED BLACK AND WHITE; TRIADS ARE CODED BLACK, WHITE, AND RED. |
| ONE CONDUCTOR IN EACH PAIR OR TRIAD IS ALSO NUMBERED FOR EASE OF IDENTIFICATION. |
| PAIRS/TRIADS: |
INSULATED CONDUCTORS TWISTED INTO PAIRS OR TRIADS WITH AN APPROXIMATE 2" LAY OF TWIST TO REDUCE CROSSTALK. |
| TWISTED PAIRS OR TRIADS INDIVIDUALLY SHIELDED WITH ALUMINUM/MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE. |
| OVERALL SHIELD: |
SHIELDED PAIRS CABLED TOGETHER WITH OVERALL ALUMINUM MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE TO PROVIDE 100% SHIELDING COVERAGE. |
| RIP CORD |
NYLON RIPCORD APPLIED UNDER JACKET TO HELP STRIP JACKET. |
| JACKET: |
SUNLIGHT AND MOISTURE RESISTANT, FLAME RETARDANT BLACK PVC. |
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Pairs |
Number of Triads |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW05190 |
18 |
- |
24 |
0.015 |
0.07 |
1.19" |
825 |
|
| CW05189 |
18 |
- |
16 |
0.015 |
0.07 |
.97" |
568 |
|
| CW05188 |
18 |
- |
12 |
0.015 |
0.06 |
.85" |
418 |
|
| CW05187 |
18 |
- |
8 |
0.015 |
0.06 |
.64" |
365 |
|
| CW05186 |
18 |
- |
4 |
0.015 |
0.05 |
.51" |
178 |
|
| CW05185 |
18 |
- |
2 |
0.015 |
0.05 |
.44" |
109 |
|
| CW05184 |
18 |
50 |
- |
0.015 |
0.08 |
1.40" |
1180 |
|
| CW05183 |
18 |
36 |
- |
0.015 |
0.07 |
1.18" |
870 |
|
| CW05182 |
18 |
24 |
- |
0.015 |
0.07 |
1.03" |
614 |
|
| CW05181 |
18 |
16 |
- |
0.015 |
0.06 |
.83" |
440 |
|
| CW05180 |
18 |
12 |
- |
0.015 |
0.06 |
.74" |
327 |
|
| CW05179 |
18 |
8 |
- |
0.015 |
0.05 |
.59" |
220 |
|
| CW05178 |
18 |
4 |
- |
0.015 |
0.05 |
.46" |
138 |
|
| CW05177 |
18 |
2 |
- |
0.015 |
0.05 |
.40" |
85 |
|
| Displaying 1 to 14 (of 14 products) |
Result Pages: 1 |
| Application |
| Instrumentation and Control Circuits rated 300volts or less. |
| Per NEC Article 725, approved for installation in |
| 1) Cable trays indoors and outdoors, |
| 2) raceways, |
| 3) supported by a messenger wire, |
| 4) hazardous locations per NEC Art.501-4(b) Class 1 Division 2, |
| 5) Cable trays in hazardous locations per NEC Art.502-4(b) Class 2 Division 2, and |
| 6) CL2 and CL3 applications. |
| Standards |
| UL Subject 13. |
| Passes UL and IEEE383 70,000BTU Flame Test. |
| NEC Article 725 Class 2 and Class 3 Circuits. |
|