INSTRUMENT CABLE - #16AWG
SHIELDED PAIRS OR TRIADS WITH OVERALL SHIELD
TYPE TC, 90°C, 600VOLTS
| Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER. |
| INSULATION: |
POLYVINYLCHLORIDE WITH 4 MILS NYLON JACKET TYPE TFN PER UL 62 (GASOLINE AND OIL RESISTANT). |
| COLOR CODE: |
PAIRS ARE CODED BLACK AND WHITE. |
| TRIADS ARE CODED BLACK. WHITE, AND RED. |
| ONE CONDUCTOR IN EACH PAIR OR TRIAD IS ALSO NUMBERED FOR EASE OF IDENTIFICATION. |
| PAIRS/TRIADS: |
INSULATED CONDUCTORS TWISTED INTO PAIRS OR TRIADS WITH AN APPROXIMATE 2" LAY OF TWIST. |
| TWISTED PAIRS OR TRIADS SHIELDED INDIVIDUALLY WITH ALUMINUM/MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE. |
| OVERALL SHIELD: |
SHIELDED PAIRS CABLED TOGETHER WITH OVERALL ALUMINUM MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE TO PROVIDE 100% SHIELDING COVERAGE. |
| RIP CORD |
NYLON RIPCORD APPLIED UNDER JACKET TO HELP STRIP JACKET. |
| JACKET: |
SUNLIGHT AND MOISTURE RESISTANT, FLAME RETARDANT BLACK PVC. |
| Charlotte Wire Part# ↓ |
Size AWG |
Number of Pairs |
Number of Triads |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW05291 |
16 |
2 |
- |
0.015 |
0.05 |
.48" |
125 |
|
| CW05292 |
16 |
3 |
- |
0.015 |
0.05 |
.51" |
143 |
|
| CW05293 |
16 |
4 |
- |
0.015 |
0.06 |
.59" |
200 |
|
| CW05294 |
16 |
6 |
- |
0.015 |
0.06 |
.69" |
268 |
|
| CW05295 |
16 |
8 |
- |
0.015 |
0.06 |
.76" |
342 |
|
| CW05296 |
16 |
12 |
- |
0.015 |
0.08 |
.96" |
515 |
|
| CW05297 |
16 |
16 |
- |
0.015 |
0.08 |
1.06" |
654 |
|
| CW05298 |
16 |
20 |
- |
0.015 |
0.08 |
1.20" |
790 |
|
| CW05299 |
16 |
24 |
- |
0.015 |
0.08 |
1.31" |
945 |
|
| CW05300 |
16 |
36 |
- |
0.015 |
0.08 |
1.54" |
1360 |
|
| CW05301 |
16 |
50 |
- |
0.015 |
0.08 |
1.85" |
1910 |
|
| CW05302 |
16 |
- |
4 |
0.015 |
0.06 |
.65" |
254 |
|
| CW05303 |
16 |
- |
8 |
0.015 |
0.08 |
.86" |
490 |
|
| CW05304 |
16 |
- |
12 |
0.015 |
0.08 |
1.03" |
683 |
|
| CW05305 |
16 |
- |
16 |
0.015 |
0.08 |
1.22" |
846 |
|
| CW05306 |
16 |
- |
24 |
0.015 |
0.08 |
1.46" |
1238 |
|
| Displaying 1 to 16 (of 16 products) |
Result Pages: 1 |
| Application |
| Control, Signal, or Lighting circuits rated 600Volts. |
| May be used as sunlight resistant, directly buried and wet or dry locations. |
| Per NEC Articles 336 and 392, approved for installation in |
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures, |
| 2) lighting, control, and signal circuits |
| 3) aerial locations where supported by a messenger wire |
| 4) hazardous locations per Art.501 Class 1 Division 2, |
| 5) Class 1 circuits as permitted in Article 725-21(B). |
| Standards |
| UL Standard 1277 for Type TC Cables. |
| Passes UL and IEEE383 70,000BTU Flame Test. |
| UL Standard 62 for TFN Conductors. |
| NEC Articles 336 and 392 for Tray Cable uses and constructions. |
|
|