INSTRUMENT CABLE - #14AWG
SHIELDED PAIRS OR TRIADS WITH OVERALL SHIELD
TYPE TC, 90°C, 600VOLTS
| Construction: |
| CONDUCTOR: |
7 STRANDED BARE COPPER. |
| INSULATION: |
POLYVINYLCHLORIDE WITH 4 MILS NYLON JACKET TYPE TFN PER UL 83. (GASOLINE AND OIL RESISTANT) |
| COLOR CODE: |
PAIRS ARE CODED BLACK AND WHITE. |
| TRIADS ARE CODED BLACK, WHITE, AND RED. |
| ONE CONDUCTOR IN EACH PAIR OR TRIAD IS ALSO NUMBERED FOR EASE OF IDENTIFICATION. |
| PAIRS/TRIADS: |
INSULATED CONDUCTORS TWISTED INTO PAIRS OR TRIADS WITH AN APPROXIMATE 3" LAY OF TWIST. |
| TWISTED PAIRS OR TRIADS SHIELDED INDIVIDUALLY WITH ALUMINUM/MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE. |
| OVERALL SHIELD: |
SHIELDED PAIRS CABLED TOGETHER WITH OVERALL ALUMINUM MYLAR TAPE SHIELD AND STRANDED TINNED COPPER DRAIN WIRE TO PROVIDE 100% SHIELDING COVERAGE. |
| RIP CORD |
NYLON RIPCORD APPLIED UNDER JACKET TO HELP STRIP JACKET. |
| JACKET: |
SUNLIGHT AND MOISTURE RESISTANT, FLAME RETARDANT BLACK PVC. |
| Charlotte Wire Part# ↓ |
Size AWG |
Number of Pairs |
Number of Triads |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW05325 |
14 |
2 |
- |
0.015 |
0.05 |
.57" |
135 |
|
| CW05326 |
14 |
4 |
- |
0.015 |
0.06 |
.66" |
260 |
|
| CW05327 |
14 |
6 |
- |
0.015 |
0.06 |
.75" |
390 |
|
| CW05328 |
14 |
8 |
- |
0.015 |
0.08 |
.90" |
500 |
|
| CW05329 |
14 |
12 |
- |
0.015 |
0.08 |
1.08" |
720 |
|
| CW05330 |
14 |
16 |
- |
0.015 |
0.08 |
1.21" |
910 |
|
| CW05331 |
14 |
20 |
- |
0.015 |
0.08 |
1.33" |
1100 |
|
| CW05332 |
14 |
24 |
- |
0.015 |
0.08 |
1.53" |
1350 |
|
| CW05333 |
14 |
36 |
- |
0.015 |
0.08 |
1.70" |
1880 |
|
| CW05334 |
14 |
50 |
- |
0.015 |
0.08 |
2.10" |
2650 |
|
| CW05340 |
14 |
- |
2 |
0.015 |
0.05 |
.53" |
140 |
|
| CW05341 |
14 |
- |
4 |
0.015 |
0.06 |
.75" |
277 |
|
| CW05342 |
14 |
- |
8 |
0.015 |
0.08 |
.86" |
530 |
|
| CW05343 |
14 |
- |
12 |
0.015 |
0.08 |
1.03" |
750 |
|
| CW05345 |
14 |
- |
24 |
0.015 |
0.08 |
1.22" |
1390 |
|
| Displaying 1 to 15 (of 15 products) |
Result Pages: 1 |
| Application |
| Control, Signal, or Lighting circuits rated 600Volts. |
| May be used as sunlight resistant, directly buried and wet or dry locations. |
| Per NEC Articles 336 and 392, approved for installation in |
| 1) raceways and cable tray systems including ladders, troughs, channels, solid bottom trays, and other similar structures, |
| 2) lighting, control, and signal circuits |
| 3) aerial locations where supported by a messenger wire |
| 4) hazardous locations per Art.501 Class 1 Division 2, |
| 5) Class 1 circuits as permitted in Article 725-21(B). |
| Standards |
| UL Standard 1277 for Type TC Cables. |
| Passes UL and IEEE383 70,000BTU Flame Test. |
| UL Standard 83 for THHN Conductors. |
| NEC 2002 Articles 336 and 392 for Tray Cable uses and constructions. |
|
|