LOW SMOKE INSTRUMENT CABLE - 16AWG
SINGLE AND MULTIPLE PAIRS AND TRIADS
TYPE TC, XLP CONDUCTORS, 90°C, 600VOLTS
| Construction: |
| CONDUCTOR: |
7 STRANDED TINNED COPPER.
|
| INSULATION: |
FLAME RETARDANT CROSSLINKED POLYETHYLENE (XLP).
|
| CONDUCTOR IDENTIFICATION: |
|
| SINGLE PAIR/TRIAD: |
PAIR IS COLOR CODED BLACK-WHITE AND TRIAD IS COLOR CODED BLACK-WHITE-RED (ICEA TABLE E-1)
|
| MULTI PAIRS/TRIADS: |
PAIRS ARE COLOR CODED BLACK-WHITE AND TRIADS ARE CODED BLACK-WHITE-RED.ONE CONDUCTOR IN EACH PAIR OR TRIAD IS ALSO NUMBERED.
|
| INDIVIDUAL PAIRS/TRIADS: |
INSULATED CONDUCTORS TWISTED INTO PAIRS OR TRIADS AND SHIELDED WITH ALUMINUM/MYLAR FOIL AND STRANDED TINNED COPPER DRAIN WIRE.
|
| OVERALL SHIELD: |
MULTIPLE SHIELDED PAIRS/TRIADS CABLED TOGETHER AND SHIELDED WITH ALUMINUM MYLER TAPE AND STRANDED TINNED DRAIN.
|
| JACKET: |
BLACK SUNLIGHT RESISTANT, FLAME RETARDANT, LOW SMOKE ZERO HALOGEN CROSSLINKED POLYETHYLENE (XLPO).
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Pairs |
Number of Triads |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW05535 |
16 |
- |
12 |
.025" |
.080" |
1.23" |
740 |
|
| CW05534 |
16 |
- |
8 |
.025" |
.080" |
1.02" |
544 |
|
| CW05533 |
16 |
- |
4 |
.025" |
.060" |
0.77" |
272 |
|
| CW05532 |
16 |
- |
2 |
.025" |
.045" |
0.62" |
175 |
|
| CW05531 |
16 |
- |
1 |
.025" |
.045" |
0.37" |
70 |
|
| CW05530 |
16 |
36 |
- |
.025" |
.080" |
1.68" |
1377 |
|
| CW05529 |
16 |
24 |
- |
.025" |
.080" |
1.44" |
948 |
|
| CW05528 |
16 |
20 |
- |
.025" |
.080" |
1.29" |
794 |
|
| CW05527 |
16 |
16 |
- |
.025" |
.080" |
1.21" |
673 |
|
| CW05526 |
16 |
12 |
- |
.025" |
.080" |
1.06" |
535 |
|
| CW05525 |
16 |
6 |
- |
.025" |
.060" |
0.78" |
274 |
|
| CW05524 |
16 |
4 |
- |
.025" |
.060" |
0.68" |
200 |
|
| CW05523 |
16 |
3 |
- |
.025" |
.060" |
0.61" |
160 |
|
| CW05522 |
16 |
2 |
- |
.025" |
.045" |
0.56" |
109 |
|
| CW05521 |
16 |
1 |
- |
.025" |
.045" |
0.35" |
55 |
|
| Displaying 1 to 15 (of 15 products) |
Result Pages: 1 |
| Application |
| Suitable for control or instrumentation circuits rated 600Volts in power plants and heavy industrial locations where flame-resistance, stability in heat, physical durability, and excellent reliability is needed.
|
| May be used as sunlight resistant, directly buried, and wet or dry locations.
|
| Standards |
| Passes UL and IEEE383 70,000 BTU and ICEA 210,000BTU flame test.
|
| ICEA S-66-524 for Crosslinked Polyethylene Wire & Cable.
|
| UL 1277 for Type TC Cable. NEC Articles 336 and 392 for Tray Cable Uses and Constructions.
|
|
|