PORTABLE CONTROL CABLE
TYPE SJOOW - #18 THROUGH #10AWG
90°C , 300VOLTS UL, CSA, AND MSHA LISTED
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
SOFT DRAWN BARE COPPER PER ASTM B-3.
|
| INSULATION: |
RUBBER COLOR CODED PER ICEA METHOD 1 TABLE E-1 OF ICEA S-73-532 (FORMERLY K-1), EXCEPT 3/C ITEMS, WHICH ARE BLACK-WHITE-GREEN.
|
| ASSEMBLY: |
INSULATED CONDUCTORS ARE CABLED TOGETHER WITH FILLERS AS NEEDED AND A SUITABLE TAPE SEPARATOR.
|
| JACKET: |
BLACK THERMOSET CPE RUBBER JACKET WHICH IS ABRASION, CHEMICAL, FLAME, OIL, SUNLIGHT, AND WATER RESISTANT.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Number of Strands |
Insulation Thickness (in.) |
Rating in Amps* |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03045 |
10 |
4 |
104 |
0.045 |
25 |
.66" |
323 |
|
| CW03044 |
10 |
3 |
104 |
0.045 |
30 |
.61" |
242 |
|
| CW03043 |
10 |
2 |
104 |
0.045 |
30 |
.57" |
208 |
|
| CW03042 |
12 |
4 |
65 |
0.03 |
20 |
.48" |
189 |
|
| CW03041 |
12 |
3 |
65 |
0.03 |
25 |
.44" |
143 |
|
| CW03040 |
12 |
2 |
65 |
0.03 |
25 |
.42" |
111 |
|
| CW03039 |
14 |
4 |
41 |
0.03 |
15 |
.42" |
126 |
|
| CW03038 |
14 |
3 |
41 |
0.03 |
18 |
.37" |
106 |
|
| CW03037 |
14 |
2 |
41 |
0.03 |
18 |
.35" |
77 |
|
| CW03036 |
16 |
4 |
26 |
0.03 |
10 |
.37" |
97 |
|
| CW03035 |
16 |
3 |
26 |
0.03 |
13 |
.34" |
77 |
|
| CW03034 |
16 |
2 |
26 |
0.03 |
13 |
.32" |
60 |
|
| CW03033 |
18 |
4 |
16 |
0.03 |
7 |
.34" |
75 |
|
| CW03032 |
18 |
3 |
16 |
0.03 |
10 |
.31" |
59 |
|
| CW03031 |
18 |
2 |
16 |
0.03 |
10 |
.29" |
49 |
|
| Displaying 1 to 15 (of 15 products) |
Result Pages: 1 |
| * Ampacities based on 30°C ambient temperature in air per the 2002 NEC, Table 400-5(A).
|
| Values shown are for current carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors is not counted in determining current carrying capacity.
|
| Application |
| For use in connection of portable equipment and appliances.
|
| Also for use on signal and control circuits in industrial plants.
|
| Designed for hard usage and for equipment that is exposed to chemicals, oils, sunlight, and moisture.
|
| Suitable for wet location use, including submersion in water.
|
| Standards |
| UL Standard 62 for flexible cords.
|
| CSA Standard C22.2 No. 49 for flexible cords.
|
| MSHA Approved: passes MSHA flame test.
|
| UL & CSA Type SJOOW: Weather resistant/outdoor.
|
| Color Code |
| 2/C Black - White
|
| 3/C Black - White - Green
|
| 4/C Black - White - Red - Green
|
|