PORTABLE CONTROL CABLE
TYPE SOOW - #18AWG
90°C 600VOLTS UL, CSA, AND MSHA LISTED

Construction:
CONDUCTOR: 16 STRANDS OF #30AWG FLEXIBLE SOFT DRAWN BARE COPPER PER ASTM B-3.
INSULATION: EPDM RUBBER COLOR CODED PER ICEA METHOD 1 TABLE E-1 OF ICEA S-73-532 (FORMERLY K-1) EXCEPT 3/C #18, WHICH IS BLACK, WHITE, AND GREEN.
ASSEMBLY: INSULATED CONDUCTORS ARE CABLED TOGETHER WITH FILLERS AS NEEDED AND A SUITABLE TAPE SEPARATOR.
JACKET: BLACK THERMOSET CPE RUBBER JACKET WHICH IS ABRASION, CHEMICAL, FLAME, OIL, OZONE, SUNLIGHT, AND WATER RESISTANT.
 Charlotte Wire Part# ↓   Size AWG   Number of Conductors   Insulation Thickness (in.)   Jacket Thickness (in.)   Rating in Amps*   Overall Diameter (in.)   Approx. Net Wt. (Lbs/Mft)   Add to Quote Cart 
CW03066 18 2 0.03 0.06 10 .34" 71 Request Quote For This Product 
CW03067 18 3 0.03 0.06 10 .36" 84 Request Quote For This Product 
CW03068 18 4 0.03 0.06 7 .39" 100 Request Quote For This Product 
CW03069 18 5 0.03 0.08 5.6 .47" 130 Request Quote For This Product 
CW03070 18 6 0.03 0.08 5.6 .50" 150 Request Quote For This Product 
CW03071 18 7 0.03 0.08 4.9 .50" 161 Request Quote For This Product 
CW03072 18 8 0.03 0.08 4.9 .53" 182 Request Quote For This Product 
CW03073 18 9 0.03 0.08 4.9 .59" 215 Request Quote For This Product 
CW03074 18 10 0.03 0.08 3.5 .61" 225 Request Quote For This Product 
CW03075 18 12 0.03 0.08 3.5 .64" 248 Request Quote For This Product 
CW03076 18 14 0.03 0.08 3.5 .66" 290 Request Quote For This Product 
CW03077 18 16 0.03 0.095 3.5 .71" 328 Request Quote For This Product 
CW03078 18 20 0.03 0.095 3.5 .80" 380 Request Quote For This Product 
CW03079 18 24 0.03 0.095 3.1 .89" 450 Request Quote For This Product 
CW03080 18 30 0.03 0.095 3.1 .96" 515 Request Quote For This Product 
CW03081 18 36 0.03 0.11 2.8 1.02" 660 Request Quote For This Product 
CW03082 18 37 0.03 0.11 2.8 1.05" 670 Request Quote For This Product 
CW03083 18 40 0.03 0.11 2.8 1.10" 715 Request Quote For This Product 
Displaying 1 to 18 (of 18 products) Result Pages:  1 
* Ampacities based on 30°C ambient temperature in air per the 2002 NEC, Table 400-5(A).
Values shown are for current carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors is not counted in determining current carrying capacity.
Application
For use in connection of portable equipment and appliances.
Also for use on signal and control circuits in industrial plants.
Designed for extra hard usage and for equipment that is exposed to chemicals, oils, sunlight, and moisture.
Suitable for wet location use, including submersion in water.
Standards
UL Standard 62 for flexible cords.
CSA Standard C22.2 No. 49 for flexible cords.
MSHA Approved: passes MSHA flame test.
UL & CSA Type SOW: Weather resistant/outdoor.
Color Code
2/C Black, White
3/C Black, White, Green
4/C Black, White, Red, Green