PORTABLE CONTROL CABLE
TYPE SOOW - #18AWG
90°C 600VOLTS UL, CSA, AND MSHA LISTED
| Construction: |
| CONDUCTOR: |
16 STRANDS OF #30AWG FLEXIBLE SOFT DRAWN BARE COPPER PER ASTM B-3.
|
| INSULATION: |
EPDM RUBBER COLOR CODED PER ICEA METHOD 1 TABLE E-1 OF ICEA S-73-532 (FORMERLY K-1) EXCEPT 3/C #18, WHICH IS BLACK, WHITE, AND GREEN.
|
| ASSEMBLY: |
INSULATED CONDUCTORS ARE CABLED TOGETHER WITH FILLERS AS NEEDED AND A SUITABLE TAPE SEPARATOR.
|
| JACKET: |
BLACK THERMOSET CPE RUBBER JACKET WHICH IS ABRASION, CHEMICAL, FLAME, OIL, OZONE, SUNLIGHT, AND WATER RESISTANT.
|
| Charlotte Wire Part# ↓ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Rating in Amps* |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03066 |
18 |
2 |
0.03 |
0.06 |
10 |
.34" |
71 |
|
| CW03067 |
18 |
3 |
0.03 |
0.06 |
10 |
.36" |
84 |
|
| CW03068 |
18 |
4 |
0.03 |
0.06 |
7 |
.39" |
100 |
|
| CW03069 |
18 |
5 |
0.03 |
0.08 |
5.6 |
.47" |
130 |
|
| CW03070 |
18 |
6 |
0.03 |
0.08 |
5.6 |
.50" |
150 |
|
| CW03071 |
18 |
7 |
0.03 |
0.08 |
4.9 |
.50" |
161 |
|
| CW03072 |
18 |
8 |
0.03 |
0.08 |
4.9 |
.53" |
182 |
|
| CW03073 |
18 |
9 |
0.03 |
0.08 |
4.9 |
.59" |
215 |
|
| CW03074 |
18 |
10 |
0.03 |
0.08 |
3.5 |
.61" |
225 |
|
| CW03075 |
18 |
12 |
0.03 |
0.08 |
3.5 |
.64" |
248 |
|
| CW03076 |
18 |
14 |
0.03 |
0.08 |
3.5 |
.66" |
290 |
|
| CW03077 |
18 |
16 |
0.03 |
0.095 |
3.5 |
.71" |
328 |
|
| CW03078 |
18 |
20 |
0.03 |
0.095 |
3.5 |
.80" |
380 |
|
| CW03079 |
18 |
24 |
0.03 |
0.095 |
3.1 |
.89" |
450 |
|
| CW03080 |
18 |
30 |
0.03 |
0.095 |
3.1 |
.96" |
515 |
|
| CW03081 |
18 |
36 |
0.03 |
0.11 |
2.8 |
1.02" |
660 |
|
| CW03082 |
18 |
37 |
0.03 |
0.11 |
2.8 |
1.05" |
670 |
|
| CW03083 |
18 |
40 |
0.03 |
0.11 |
2.8 |
1.10" |
715 |
|
| Displaying 1 to 18 (of 18 products) |
Result Pages: 1 |
| * Ampacities based on 30°C ambient temperature in air per the 2002 NEC, Table 400-5(A).
|
| Values shown are for current carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors is not counted in determining current carrying capacity.
|
| Application |
| For use in connection of portable equipment and appliances.
|
| Also for use on signal and control circuits in industrial plants.
|
| Designed for extra hard usage and for equipment that is exposed to chemicals, oils, sunlight, and moisture.
|
| Suitable for wet location use, including submersion in water.
|
| Standards |
| UL Standard 62 for flexible cords.
|
| CSA Standard C22.2 No. 49 for flexible cords.
|
| MSHA Approved: passes MSHA flame test.
|
| UL & CSA Type SOW: Weather resistant/outdoor.
|
| Color Code |
| 2/C Black, White
|
| 3/C Black, White, Green
|
| 4/C Black, White, Red, Green
|
|
|