PORTABLE CONTROL CABLE
TYPE SOOW - #12AWG
90°C 600VOLTS UL, CSA, AND MSHA LISTED
| Construction: |
| CONDUCTOR: |
65 STRANDS OF #30AWG FLEXIBLE SOFT DRAWN BARE COPPER PER ASTM B-3. |
| INSULATION: |
EPDM RUBBER COLOR CODED PER ICEA METHOD 1 TABLE E-1 OF ICEA S-73-532 (FORMERLY K-1), EXCEPT 3/C #12, WHICH IS BLACK, WHITE, AND GREEN. |
| ASSEMBLY: |
INSULATED CONDUCTORS ARE CABLED TOGETHER WITH FILLERS AS NEEDED AND A SUITABLE TAPE SEPARATOR. |
| JACKET: |
BLACK THERMOSET CPE RUBBER JACKET WHICH IS ABRASION, CHEMICAL, FLAME, OIL, OZONE, SUNLIGHT, AND WATER RESISTANT. |
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Insulation Thickness (in.) |
Jacket Thickness (in.) |
Rating in Amps* |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03161 |
12 |
40 |
0.045 |
0.125 |
8 |
1.63" |
1980 |
|
| CW03160 |
12 |
37 |
0.045 |
0.125 |
8 |
1.57" |
1778 |
|
| CW03159 |
12 |
36 |
0.045 |
0.125 |
8 |
1.57" |
1740 |
|
| CW03158 |
12 |
30 |
0.045 |
0.125 |
9 |
1.49" |
1460 |
|
| CW03157 |
12 |
24 |
0.045 |
0.125 |
9 |
1.35" |
1225 |
|
| CW03156 |
12 |
20 |
0.045 |
0.11 |
10 |
1.21" |
1055 |
|
| CW03155 |
12 |
16 |
0.045 |
0.11 |
10 |
1.10" |
890 |
|
| CW03154 |
12 |
12 |
0.045 |
0.095 |
10 |
.96" |
680 |
|
| CW03153 |
12 |
10 |
0.045 |
0.095 |
10 |
.91" |
584 |
|
| CW03152 |
12 |
9 |
0.045 |
0.095 |
14 |
.87" |
540 |
|
| CW03151 |
12 |
8 |
0.045 |
0.095 |
14 |
.81" |
488 |
|
| CW03150 |
12 |
7 |
0.045 |
0.095 |
14 |
.75" |
415 |
|
| CW03149 |
12 |
6 |
0.045 |
0.095 |
16 |
.75" |
386 |
|
| CW03148 |
12 |
5 |
0.045 |
0.095 |
16 |
.71" |
350 |
|
| CW03147 |
12 |
4 |
0.045 |
0.095 |
20 |
.65" |
286 |
|
| CW03146 |
12 |
3 |
0.045 |
0.095 |
25 |
.60" |
235 |
|
| CW03145 |
12 |
2 |
0.045 |
0.095 |
25 |
.58" |
190 |
|
| Displaying 1 to 17 (of 17 products) |
Result Pages: 1 |
| * Ampacities based on 30°C ambient temperature in air per the 2002 NEC, Table 400-5(A). |
| Values shown are for current carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors is not counted in determining current carrying capacity. |
| Application |
| For use in connection of portable equipment and appliances. |
| Also for use on signal and control circuits in industrial plants. |
| Designed for extra hard usage and for equipment that is exposed to chemicals, oils, sunlight, and moisture. |
| Suitable for wet location use, including submersion in water. |
| Standards |
| UL Standard 62 for flexible cords. |
| CSA Standard C22.2 No. 49 for flexible cords. |
| MSHA Approved: passes MSHA flame test. |
| UL & CSA Type SOW: Weather resistant/outdoor. |
|
|