PORTABLE CABLE - YELLOW (18 THRU 2AWG)
TYPE SEOOW, 105°C, 600VOLTS, MSHA LISTED
(UL & CSA LISTED IN SIZES #18 THRU #10AWG)
| Construction: |
| CONDUCTOR: |
FLEXIBLE STRANDS OF SOFT DRAWN BARE COPPER.
|
| INSULATION: |
OIL RESISTANT THERMOPLASTIC ELASTOMER INDIVIDUALLY COLOR CODED.
|
| ASSEMBLY: |
INSULATED CONDUCTORS CABLED TOGETHER WITH WATER RESISTANT, NON-WICKING FILLERS.
|
| JACKET: |
YELLOW LIGHTWEIGHT THERM0PLASTIC ELASTOMER WHICH IS ABRASION, CHEMICAL, FLAME, OIL, OZONE, AND WATER RESISTANT.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Conductors |
Number of Strands |
Insulation Thickness (in.) |
Rating in Amps* |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03237 |
2 |
4 |
133 |
0.05 |
80 |
1.29" |
1230 |
|
| CW03236 |
2 |
3 |
133 |
0.05 |
95 |
1.18" |
980 |
|
| CW03235 |
4 |
4 |
96 |
0.05 |
60 |
1.10" |
870 |
|
| CW03234 |
4 |
3 |
96 |
0.05 |
70 |
.98" |
680 |
|
| CW03233 |
6 |
4 |
96 |
0.05 |
45 |
.89" |
605 |
|
| CW03232 |
6 |
3 |
96 |
0.05 |
55 |
.81" |
460 |
|
| CW03231 |
8 |
4 |
96 |
0.05 |
35 |
.78" |
422 |
|
| CW03230 |
8 |
3 |
96 |
0.05 |
40 |
.71" |
330 |
|
| CW03229 |
10 |
4 |
104 |
0.045 |
25 |
.72" |
302 |
|
| CW03228 |
10 |
3 |
104 |
0.045 |
30 |
.66" |
241 |
|
| CW03227 |
10 |
2 |
104 |
0.045 |
30 |
.63" |
207 |
|
| CW03226 |
12 |
4 |
65 |
0.045 |
20 |
.65" |
226 |
|
| CW03225 |
12 |
3 |
65 |
0.045 |
25 |
.60" |
184 |
|
| CW03224 |
12 |
2 |
65 |
0.045 |
25 |
.58" |
155 |
|
| CW03223 |
14 |
4 |
41 |
0.045 |
15 |
.58" |
165 |
|
| CW03222 |
14 |
3 |
41 |
0.045 |
18 |
.54" |
135 |
|
| CW03221 |
14 |
2 |
41 |
0.045 |
18 |
.51" |
116 |
|
| CW03220 |
16 |
4 |
26 |
0.03 |
10 |
.42" |
92 |
|
| CW03219 |
16 |
3 |
26 |
0.03 |
13 |
.40" |
76 |
|
| CW03218 |
16 |
2 |
26 |
0.03 |
13 |
.38" |
65 |
|
| CW03217 |
18 |
4 |
16 |
0.03 |
7 |
.40" |
77 |
|
| CW03216 |
18 |
3 |
16 |
0.03 |
10 |
.37" |
69 |
|
| CW03215 |
18 |
2 |
16 |
0.03 |
10 |
.35" |
55 |
|
| Displaying 1 to 23 (of 23 products) |
Result Pages: 1 |
| * Ampacities based on 90°C temperature rating and 30°C ambient temperature in air per NEC Table 400-5(A).
|
| Values shown are for current carrying conductors. A grounding conductor, or one which carries only the unbalance current from other conductors is not counted in determining current carrying capacity.
|
| Application |
| For use in connection of portable equipment and appliances.
|
| Also for use on signal and control circuits in industrial plants.
|
| Designed for extra hard usage and for equipment that is exposed to chemicals, oils, and moisture.
|
| Suitable for wet location use, including submersion in water.
|
| Superior abrasion resistance and approximately 20% lighter in weight compared to standard rubber cords.
|
| Standards |
| UL Type SEOOW and CSA Type STW: weather resistant/outdoor(18-10AWG).
|
| Low temperature rating: 40°C UL, -50°C CSA.
|
| MSHA Approved: Passes MSHA flame test.
|
| Color Code |
| 2/C Black, White
|
| 3/C Black, White, Green
|
| 4/C Black, White, Red, Green
|
|
|