DIESEL LOCOMOTIVE CABLE
SINGLE CONDUCTOR FLEXIBLE POWER CABLE
90°C 600/2000VOLTS MSHA, UL RHH/RHW
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
FLEXIBLE STRANDED TINNED SOFT DRAWN COPPER PER AAR.
|
| SEPARATOR: |
A SUITABLE TAPE SEPARATOR IS BETWEEN THE CONDUCTOR AND THE INSULATION WHERE NECESSARY TO AID STRIPPING.
|
| INSULATION: |
90°C ETHYLENE PROPYLENE RUBBER (EPR).
|
| JACKET: |
HEAVY DUTY BLACK THERMOSETTING RUBBER COMPOUND WITH RESISTANCE TO FLAME, CHEMICAL, OIL, AND ABRASION.
|
| Charlotte Wire Part# ↑ |
Size AWG |
Number of Strands |
Conductor Diameter (in.) |
3/C Amps* |
1/C Amps** |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03390 |
1111MCM |
2745 |
1.35" |
615 |
1119 |
1.80" |
4300 |
|
| CW03389 |
929MCM |
2318 |
1.25" |
585 |
1005 |
1.63" |
3550 |
|
| CW03388 |
777MCM |
1925 |
1.11" |
546 |
904 |
1.49" |
2920 |
|
| CW03387 |
646MCM |
1600 |
1.03" |
493 |
815 |
1.42" |
2500 |
|
| CW03386 |
535MCM |
1325 |
.92" |
445 |
728 |
1.32" |
2110 |
|
| CW03385 |
444MCM |
1100 |
.84" |
400 |
652 |
1.16" |
1758 |
|
| CW03384 |
373MCM |
925 |
.77" |
362 |
591 |
1.09" |
1490 |
|
| CW03383 |
313MCM |
775 |
.70" |
326 |
522 |
1.03" |
1260 |
|
| CW03382 |
262MCM |
650 |
.64" |
296 |
467 |
.96" |
1080 |
|
| CW03381 |
4/0 |
550 |
.59" |
260 |
405 |
.84" |
890 |
|
| CW03380 |
3/0 |
450 |
.54" |
225 |
350 |
.82" |
775 |
|
| CW03379 |
2/0 |
325 |
.45" |
195 |
300 |
.71" |
565 |
|
| CW03378 |
1/0 |
275 |
.41" |
170 |
260 |
.68" |
490 |
|
| CW03377 |
1 |
225 |
.38" |
150 |
220 |
.64" |
420 |
|
| CW03376 |
2 |
150 |
.31" |
130 |
190 |
.51" |
269 |
|
| CW03375 |
4 |
105 |
.26" |
95 |
140 |
.45" |
205 |
|
| CW03374 |
6 |
61 |
.21" |
75 |
105 |
.37" |
129 |
|
| CW03373 |
8 |
37 |
.14" |
55 |
80 |
.30" |
84 |
|
| CW03372 |
10 |
27 |
.12" |
40 |
55 |
.25" |
58 |
|
| CW03371 |
12 |
19 |
.09" |
30 |
40 |
.23" |
43 |
|
| CW03370 |
14 |
19 |
.07" |
25 |
35 |
.21" |
31 |
|
| Displaying 1 to 21 (of 21 products) |
Result Pages: 1 |
| * Ampacities based on 90°C Conductor and 30°C Ambient Temperature with not more than three current-carrying conductors in raceway, cable or earth per NEC 310-16.
|
| ** Ampacities based on single conductor in free air, 90°C conductor temperature, 30°C ambient temperature from NEC 310-17.
|
| Application |
| Suitable for use in locomotive and car equipment wiring, motor leads, portable power systems, cranes, hoists, shipyards, temporary power, electrical moving equipment, and other applications using a heavy duty flexible power cable.
|
| Standards |
| Passes MSHA flame test.
|
| Applicable standards of AAR.
|
| NEC Type RHH/RHW.
|
| For CT Use (1/0 AWG and Larger).
|
| Sunlight Resistant
|
|