PORTABLE POWER CABLE
UL TYPE G-GC THREE CONDUCTOR ROUND
90°C, 600/2000VOLTS
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
FLEXIBLE SOFT DRAWN BARE COPPER.
|
| INSULATION: |
90°C THERMOSET EPDM RUBBER, COLOR CODED BLACK, WHITE, AND RED.
|
| ASSEMBLY: |
INSULATED POWER CONDUCTORS CABLED TOGETHER WITH A GROUND CONDUCTOR IN TWO OF THE INTERSTICES AND A GROUND CHECK IN THE THIRD INTERSTICE.
|
| GROUND CONDUCTORS: |
TWO FLEXIBLE BARE COPPER CONDUCTORS WITH GREEN RUBBER COVERING.
|
| GROUND CHECK: |
FLEXIBLE BARE COPPER CONDUCTOR WITH YELLOW RUBBER COMPOUND.
|
| JACKET: |
EXTRA HARD USAGE BLACK THERMOSET CPE THAT IS RESISTANT TO ABRASION, OIL, CHEMICALS, SUNLIGHT, AND WATER.
|
| Charlotte Wire Part# ↓ |
Size AWG |
No. of Cdrs |
Number of Strands |
Insulation Thickness (in.) |
Ground Wire Size |
Ground Check Size |
Rating in Amps* |
O.D. (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW03501 |
8 |
3 |
133 |
0.06 |
2-#10 |
10 |
65 |
.99" |
655 |
|
| CW03502 |
6 |
3 |
133 |
0.06 |
2-#10 |
10 |
87 |
1.06" |
860 |
|
| CW03503 |
4 |
3 |
133 |
0.06 |
2- #8 |
10 |
114 |
1.19" |
1200 |
|
| CW03504 |
2 |
3 |
133 |
0.06 |
2- #7 |
10 |
152 |
1.34" |
1590 |
|
| CW03505 |
1 |
3 |
133 |
0.08 |
2- #6 |
8 |
177 |
1.51" |
2040 |
|
| CW03506 |
1/0 |
3 |
259 |
0.08 |
2- #5 |
8 |
205 |
1.65" |
2530 |
|
| CW03507 |
2/0 |
3 |
259 |
0.08 |
2- #4 |
8 |
237 |
1.75" |
2970 |
|
| CW03508 |
3/0 |
3 |
259 |
0.08 |
2- #3 |
8 |
274 |
1.89" |
3490 |
|
| CW03509 |
4/0 |
3 |
259 |
0.08 |
2- #2 |
8 |
316 |
2.04" |
4430 |
|
| CW03510 |
250MCM |
3 |
427 |
0.095 |
2- #2 |
8 |
352 |
2.39" |
5970 |
|
| CW03511 |
350MCM |
3 |
427 |
0.095 |
2- 1/0 |
8 |
433 |
2.68" |
7350 |
|
| CW03512 |
500MCM |
3 |
427 |
0.095 |
2- 2/0 |
8 |
536 |
3.03" |
9970 |
|
| Displaying 1 to 12 (of 12 products) |
Result Pages: 1 |
| * Ampacity based on three current carrying conductors, 30°C ambient temperature, and 90°C conductor temperature per 2002 NEC Table 400-5(B).
|
| Application |
| Suitable for use on mobile mining equipment, conveyors, pumps, temporary power supply, and portable heavy duty equipment.
|
| Ground check conductor allows for fail-safe ground monitoring.
|
| Designed for extra hard usage and for equipment that is exposed to chemicals, oil, sunlight, and moisture.
|
| Suitable for wet location use, including submersion in water.
|
| Standards |
| Passes MSHA flame test.
|
| Insulation per ICEA standards.
|
| NEC Type G-GC.
|
| Color Code |
| 3/C Black, White, and Red
|
|