THERMOCOUPLE WIRE
SINGLE PAIR 260°C PFA TEFLON®
SOLID CONDUCTOR, NONSHIELDED/SHIELDED
| Construction: |
| CONDUCTOR: |
SOLID ALLOYS PER ANSI STANDARDS. (SEE TABLE BELOW).
|
| INSULATION: |
PFA TEFLON® COLOR CODED PER ANSI STANDARDS.
|
| ASSEMBLY: |
IN NONSHIELDED CONSTRUCTION, INSULATED CONDUCTORS ARE LAID PARALLEL.
|
| IN SHIELDED CONSTRUCTION, INSULATED CONDUCTORS ARE TWISTED TOGETHER WITH OVERALL ALUMINUM MYLAR TAPE AND TINNED COPPER DRAIN WIRE.
|
| JACKET: |
260°C PFA TEFLON® COLOR CODED PER ANSI STANDARDS.
|
| RATED 260°C/500°F CONTINUOUS OR 288°C/550°F FOR SINGLE READING.
|
| Charlotte Wire Part# ↓ |
A.N.S.I Type |
Size AWG |
Number of Strands |
Shielding Type |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW06121 |
J |
24 |
1 |
Nonshielded |
.06" x .09" |
7 |
|
| CW06122 |
J |
20 |
1 |
Nonshielded |
.09" x .14" |
11 |
|
| CW06123 |
J |
20 |
1 |
Shielded |
.14" |
22 |
|
| CW06124 |
K |
24 |
1 |
Nonshielded |
.06" x .09" |
7 |
|
| CW06125 |
K |
20 |
1 |
Nonshielded |
.09" x .14" |
11 |
|
| CW06126 |
K |
20 |
1 |
Shielded |
.14" |
22 |
|
| CW06127 |
E |
24 |
1 |
Nonshielded |
.06" x .09" |
7 |
|
| CW06128 |
E |
20 |
1 |
Nonshielded |
.09" x .14" |
11 |
|
| CW06129 |
E |
20 |
1 |
Shielded |
.14" |
22 |
|
| CW06130 |
T |
24 |
1 |
Nonshielded |
.06" x .09" |
7 |
|
| CW06131 |
T |
20 |
1 |
Nonshielded |
.09" x .14" |
11 |
|
| CW06132 |
T |
20 |
1 |
Shielded |
.14" |
22 |
|
| Displaying 1 to 12 (of 12 products) |
Result Pages: 1 |
| ® PFA Teflon® is a registered trademark of Dupont.
|
| Application |
| Suitable for temperature measurement in power plants, petroleum plants, heat treating, food processing plants, and other industrial locations.
|
| PFA Teflon®'s abrasion resistance and smoothness allows for easy pulling.
|
| PFA Teflon® also has excellent flame, oil, chemical, sunlight, and moisture resistance.
|
| Optional Constructions |
| Special calibration tolerance.
|
| Overall metallic coverings such as stainless steel overbraid.
|
| Thermocouple Identification |
| A.N.S.I. Type |
Positive Wire Type |
Negative Wire Type |
Positive Wire Color |
Negative Wire Color |
Overall Jacket Color |
Limits of Error (°C or %)*
|
| J |
Iron |
Constantan |
White |
Red |
Brown |
+/-2.2C or .75%
|
| K |
Chromel |
Alumel |
Yellow |
Red |
Brown |
+/-2.2C or .75%
|
| E |
Chromel |
Constantan |
Purple |
Red |
Brown |
+/-1.7C or .50%
|
| T |
Copper |
Constantan |
Blue |
Red |
Brown |
+/-1.0C or .75%
|
| * For limits of error, the greater temperature difference is to be used. |
|
|
|
|
|
|
|
|