THERMOCOUPLE WIRE
SINGLE PAIR 482°C FIBER GLASS
SOLID CONDUCTOR, NONSHIELDED

Construction:
CONDUCTOR: SOLID ALLOYS PER ANSI STANDARDS. (SEE TABLE BELOW).
INSULATION: COLOR CODED FIBER GLASS BRAID SATURATED WITH HIGH PERFORMANCE RESIN.
ASSEMBLY: INSULATED CONDUCTORS ARE LAID PARALLEL AND COVERED WITH JACKET.
JACKET: FIBER GLASS COLOR CODED PER ANSI STANDARDS.
RATED 482°C/900°F CONTINUOUS OR 538°C/1000°F FOR SINGLE READING.
 Charlotte Wire Part# ↑   A.N.S.I Type   Size AWG   Number of Strands   Shielding Type   Overall Diameter (in.)   Approx. Net Wt. (Lbs/Mft)   Add to Quote Cart 
CW06152 K 16 1 Nonshielded .10" x .17" 20 Request Quote For This Product 
CW06151 J 16 1 Nonshielded .10" x .17" 20 Request Quote For This Product 
CW06150 K 18 1 Nonshielded .08" x .13" 13 Request Quote For This Product 
CW06149 J 18 1 Nonshielded .08" x .13" 13 Request Quote For This Product 
CW06148 T 20 1 Nonshielded .06" x .10" 9 Request Quote For This Product 
CW06147 T 24 1 Nonshielded .05" x .08" 6 Request Quote For This Product 
CW06146 E 20 1 Nonshielded .06" x .10" 9 Request Quote For This Product 
CW06145 E 24 1 Nonshielded .05" x .08" 6 Request Quote For This Product 
CW06144 K 20 1 Nonshielded .06" x .10" 9 Request Quote For This Product 
CW06143 K 24 1 Nonshielded .05" x .08" 6 Request Quote For This Product 
CW06142 J 20 1 Nonshielded .06" x .10" 9 Request Quote For This Product 
CW06141 J 24 1 Nonshielded .05" x .08" 6 Request Quote For This Product 
Displaying 1 to 12 (of 12 products) Result Pages:  1 
Application
Suitable for temperature measurement in glass plants, brick plants, ceramic plants, foundries, metals plants, and heat treating.
In addition to its high heat resistance, fiber glass thermocouple wire also has good moisture and chemical resistance.
Optional Constructions
Special calibration tolerance.
Overall metallic coverings such as stainless steel overbraid.
Other AWG sizes.
Thermocouple Identification
A.N.S.I. Type Positive Wire Type Negative Wire Type Positive Wire Color Negative Wire Color Overall Jacket Color Limits of Error (°C or %)*
J Iron Constantan White Red Brown +/-2.2C or .75%
K Chromel Alumel Yellow Red Brown +/-2.2C or .75%
E Chromel Constantan Purple Red Brown +/-1.7C or .50%
T Copper Constantan Blue Red Brown +/-1.0C or .75%
* For limits of error, the greater temperature difference is to be used.