INTERLOCKED ARMOR CABLE
3 CONDUCTOR W/GROUND 15KV SHIELDED
EPR INSULATION , 133% INSULATION LEVEL
UL TYPE MC , MV-105 , CT USE
| Construction: |
| CONDUCTOR: |
CLASS B STRANDED BARE COPPER.
|
| INSULATION: |
THERMOSETTING ETHYLENE PROPYLENE RUBBER (EPR).
|
| CONDUCTOR IDENTIFICATION: |
PHASE CODED WITH SUITABLE MARKING ON EACH CONDUCTOR.
|
| CONDUCTOR ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH STRANDED COPPER GROUND IN ONE OF THE INTERSTICES, SUITABLE FILLERS WHERE NECESSARY, AND OVERALL CABLE BINDER TAPE.
|
| ARMOR: |
ALUMINUM INTERLOCKED ARMOR APPLIED OVER CABLE ASSEMBLY.
|
| STRAND SHIELD: |
EXTRUDED NONMETALLIC SEMI-CONDUCTING LAYER.
|
| INSULATION SHIELDING: |
|
| NONMETALLIC LAYER: |
SEMI-CONDUCTING LAYER DIRECTLY OVER INSULATION.
|
| METALLIC LAYER: |
LAPPED COPPER TAPE DIRECTLY OVER NONMETALLIC LAYER.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT RED PVC APPLIED OVER INTERLOCKED ARMOR.
|
| Charlotte Wire Part# ↓ |
Size AWG |
Insulation Thickness (in.) |
Ground Size (AWG) |
Armor Diameter (in.) |
PVC Jkt Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Amps * |
Add to Quote Cart |
| CW08701 |
2 |
0.22" |
1 - #6 |
2.13" |
0.060" |
2.25" |
2580 |
165 |
|
| CW08702 |
1 |
0.22" |
1 - #4 |
2.22" |
0.060" |
2.34" |
2800 |
185 |
|
| CW08703 |
1/0 |
0.22" |
1 - #4 |
2.32" |
0.060" |
2.44" |
3160 |
215 |
|
| CW08704 |
2/0 |
0.22" |
1 - #4 |
2.41" |
0.075" |
2.56" |
3590 |
245 |
|
| CW08705 |
3/0 |
0.22" |
1 - #3 |
2.52" |
0.075" |
2.67" |
4000 |
280 |
|
| CW08706 |
4/0 |
0.22" |
1 - #3 |
2.65" |
0.075" |
2.80" |
4640 |
320 |
|
| CW08707 |
250MCM |
0.22" |
1 - #3 |
2.78" |
0.075" |
2.93" |
5300 |
350 |
|
| CW08708 |
350MCM |
0.22" |
1 - #2 |
3.02" |
0.075" |
3.17" |
6620 |
430 |
|
| CW08709 |
500MCM |
0.22" |
1 - #1 |
3.31" |
0.085" |
3.48" |
8690 |
525 |
|
| CW08710 |
750MCM |
0.22" |
1 - 1/0 |
3.70" |
0.085" |
3.87" |
11900 |
635 |
|
| CW08711 |
1000MCM |
0.22" |
1 - 1/0 |
4.06" |
0.085" |
4.23" |
14850 |
725 |
|
| Displaying 1 to 11 (of 11 products) |
Result Pages: 1 |
| * Ampacity based on 3 conductor in isolated conduit in air with 105°C conductor temperature and 40°C ambient temperature per 2002 NEC Table 310.75.
|
| Application |
| Suitable for power circuits rated up to 15000Volts 133% Insulation Level (ungrounded) in industrtial, commercial, and utility locations.
|
| Per NEC Article 330, may be used
|
| 1) indoors or outdoors,
|
| 2) raceways and cable tray systems including ladders, troughs, and channels,
|
| 3) aerial cable on a messenger, and
|
| 4) in hazardous locations per NEC Class 1 Division 2, Class II Division 2, and Class III Division 1 and 2.
|
| Standards |
| Passes UL & IEEE 70,000BTU Flame Test.
|
| ICEA S-93-639/NEMA WC74 for Shielded Power Cables. (Formerly ICEA S-68-516/NEMA WC-8).
|
| UL 1072 for Medium Voltage Cables.
|
| NEC Article 330 for Metal Clad Cable.
|
| NEC Article 392 for Tray Use.
|
| Optional Constructions |
| XLP insulation.
|
| PVC jackets on singles.
|
| Different ground wire sizes.
|
| Galvanized steel armor.
|
| Different colors on outer PVC jacket.
|
|
|