CONTINUOUS CORRUGATED ARMORED CABLE
12AWG WITH GROUND
TYPE MC-HL, CT USE, SUN RESISTANT, DIRECT BURIAL
XHHW-2 CONDUCTORS, 90°C WET OR DRY
Click  for Printer Friendly Spec Sheet. | Construction: |
| CONDUCTOR: |
CLASS B STRANDED BARE COPPER.
|
| INSULATION: |
THERMOSETTING CROSSLINKED POLYETHYLENE (XLP) XHHW-2.
|
| CONDUCTOR IDENTIFICATION: |
COLOR CODED PER ICEA S-73-532 METHOD 1 TABLE E-2.
|
| ASSEMBLY: |
CONDUCTORS ARE CABLED TOGETHER WITH STRANDED COPPER GROUND WIRE, AND OVERALL CABLE BINDER TAPE.
|
| ARMOR: |
CONTINUOUS CORRUGATED ALUMINUM ARMOR WHICH IS IMPERVIOUS TO LIQUIDS, MOISTURE, AND GASES.
|
| OVERALL JACKET: |
SUNLIGHT RESISTANT, FLAME RETARDANT BLACK PVC APPLIED OVER ARMOR.
|
| Charlotte Wire Part# ↑ |
Size AWG |
No. of Condr's |
Insulation Thickness (in.) |
Ground Sizes (AWG) |
Armor Diameter (in.) |
PVC Jkt Thickness (in.) |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW08476 |
12 |
37 |
.030" |
1 - #12 |
1.39" |
.050" |
1.49" |
1410 |
|
| CW08475 |
12 |
25 |
.030" |
1 - #12 |
1.21" |
.050" |
1.31" |
1050 |
|
| CW08474 |
12 |
19 |
.030" |
1 - #12 |
0.99" |
.050" |
1.09" |
770 |
|
| CW08473 |
12 |
15 |
.030" |
1 - #12 |
0.96" |
.050" |
1.06" |
670 |
|
| CW08472 |
12 |
12 |
.030" |
1 - #12 |
0.88" |
.050" |
0.98" |
538 |
|
| Cw08471 |
12 |
9 |
.030" |
1 - #12 |
0.81" |
.050" |
0.91" |
445 |
|
| CW08470 |
12 |
7 |
.030" |
1 - #12 |
0.67" |
.050" |
0.77" |
370 |
|
| CW08469 |
12 |
5 |
.030" |
1 - #12 |
0.63" |
.050" |
0.73" |
310 |
|
| CW08468 |
12 |
4 |
.030" |
1 - #12 |
0.58" |
.050" |
0.68" |
245 |
|
| CW08467 |
12 |
3 |
.030" |
1 - #12 |
0.56" |
.050" |
0.66" |
222 |
|
| CW08466 |
12 |
2 |
.030" |
1 - #12 |
0.51" |
.050" |
0.61" |
190 |
|
| Displaying 1 to 11 (of 11 products) |
Result Pages: 1 |
| Application |
| Suitable for power, lighting, control, and signal circuits in a variety of industrial locations including pulp and paper, chemical, and petrochemical.
|
| Continuous corrugated armor provides excellent mechanical resistance and can be used as an electrical shield when adequate grounding is maintained. Per NEC Article 330, may be used 1)indoors or outdoors, 2)in raceway or cable tray, 3)as aerial cable on a messenger, 4)in direct burial applications, and 5)in hazardous locations per NEC Class I, II, and III, Divisions 1 and 2.
|
| Standards |
| UL Standard 1569 for Type MC Cables.
|
| Passes UL & IEEE 70,000BTU Flame Test.
|
| UL Standard 44 for XHHW-2 conductors.
|
| ICEA S-95-658/NEMA WC70 for Nonshielded 0 - 2KV Cables. (Formerly ICEA S-66-524/NEMA WC7).
|
| NEC Article 330 for Metal Clad Uses and Constructions.
|
| UL Standard 2225 for Metal Clad Cables in Hazardous Locations.
|
|