MULTIPAIR PLENUM CABLE
NONSHIELDED PAIRS WITH OVERALL SHIELD
NEC ARTICLES 725/800, TYPE CL2P/CMP 75°C

Construction:
CONDUCTOR: 7 STRANDED BARE COPPER.
INSULATION: PLENUM RATED PVC COPOLYMER INDIVIDUALLY COLOR CODED.
ASSEMBLY: INSULATED CONDUCTORS TWISTED INTO PAIRS AND CABLED WITH ALUMINUM/MYLAR TAPE SHIELD AND TINNED COPPER DRAIN WIRE.
JACKET: PLENUM RATED PVC COPOLYMER COLORED WHITE/NATURAL.
 Charlotte Wire Part# ↓   Size AWG   Number of Pairs   Number of Strands   Insulation Thickness (in.)   Jacket Thickness (in.)   Overall Diameter (in.)   Net Wt. (Lbs/Mft)   Add to Quote Cart 
CW09441 22 2 7 0.008 0.015 .19" 20 Request Quote For This Product 
CW09442 22 3 7 0.008 0.015 .21" 25 Request Quote For This Product 
CW09443 22 4 7 0.008 0.015 .23" 31 Request Quote For This Product 
CW09444 22 6 7 0.008 0.015 .27" 48 Request Quote For This Product 
CW09445 20 2 7 0.008 0.015 .25" 29 Request Quote For This Product 
CW09446 20 3 7 0.008 0.015 .27" 40 Request Quote For This Product 
CW09447 20 4 7 0.008 0.015 .30" 51 Request Quote For This Product 
CW09448 18 2 7 0.009 0.015 .28" 42 Request Quote For This Product 
CW09449 18 3 7 0.009 0.015 .30" 54 Request Quote For This Product 
CW09450 18 4 7 0.009 0.015 .32" 75 Request Quote For This Product 
Displaying 1 to 10 (of 10 products) Result Pages:  1 
Application
Suitable for use in ducts, plenums, and other space used for environmental air and shall also be listed as having adequate fire resistant and low smoke producing characteristics.
Used in sound/audio systems, intercom/P.A. systems, security systems, power limited controls, and remote control signalling.
Standards
NEC Article 725 (Type CL2P).
NEC Article 800 (Type CMP).
Optional Constructions
Tinned Copper.
Colored Jackets.
Other Insulation/Jacket Materials such as Kynar®, Solef®, and FEP Teflon®.
COLOR CODE CHART
(Pair #:Pair Colors)
1 Black & Red 3 Black & Green 5 Black & Yellow
2 Black & White 4 Black & Blue 6 Black & Brown