OUTSIDE PLANT TELEPHONE CABLE
FOAM-SKIN, FILLED, DIRECT BURIAL
RUS (REA) PE-89 #24 AWG
| Construction: |
| CONDUCTOR: |
SOLID ANNEALED BARE COPPER.
|
| TWO-LAYER INSULATION: |
1) INNER LAYER OF FOAMED POLYOLEFIN.
|
| 2) OUTER SKIN OF SOLID COLOR CODED POLYOLEFIN.
|
| CORE ASSEMBLY: |
INSULATED CONDUCTORS ARE TWISTED INTO PAIRS OF VARYING TWIST LENGTHS TO MINIMIZE CROSSTALK.
|
| CABLES OF 25PAIRS OR LESS ARE ASSEMBLED INTO A SINGLE GROUP.
|
| CABLES OVER 25PAIRS ARE ARRANGED INTO SUBUNITS.
|
| A FLOODING COMPOUND IS APPLIED TO THE ENTIRE CORE ASSEMBLY, COMPLETELY FILLING THE AIR SPACE BETWEEN THE INSULATED CONDUCTORS AND ALSO UNDER THE NON-HYGROSCOPIC TAPE WHICH WRAPS THE CABLE CORE.
|
| SHIELD: |
.008"INCH(8 MIL) COATED CORRUGATED ALUMINUM TAPE APPLIED LONGITUDINALLY.
|
| OVERALL JACKET: |
BLACK POLYETHYLENE.
|
| Charlotte Wire Part#* ↓ |
Size AWG |
Number of Pairs |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW09771 |
24 |
6 |
.41" |
75 |
|
| CW09772 |
24 |
12 |
.47" |
105 |
|
| CW09773 |
24 |
25 |
.58" |
164 |
|
| CW09774 |
24 |
50 |
.74" |
270 |
|
| CW09775 |
24 |
100 |
.92" |
480 |
|
| CW09776 |
24 |
150 |
1.11" |
680 |
|
| CW09777 |
24 |
200 |
1.22" |
868 |
|
| CW09778 |
24 |
300 |
1.45" |
1290 |
|
| CW09779 |
24 |
400 |
1.63" |
1650 |
|
| CW09780 |
24 |
600 |
2.00" |
2440 |
|
| CW09781 |
24 |
900 |
2.37" |
3610 |
|
| CW09782 |
24 |
1200 |
2.74" |
4750 |
|
| CW09783 |
24 |
1500 |
3.00" |
5900 |
|
| CW09784 |
24 |
1800 |
3.24" |
7240 |
|
| Displaying 1 to 14 (of 14 products) |
Result Pages: 1 |
| * Note: To Specify alternate longitudinal shield to standard, add suffixes to CWC part# as follows:
|
| 1) for 5mil corrugated copper tape, add suffix "-CU" to CWC part#.
|
| 2) for 5-6mil corrugated copper clad steel or alloy gopher resistant tape, add suffix "-GO" to CWC part#.
|
| 3) for dual 8mil aluminum plus 6mil steel tape, add suffix "-ALS" to CWC part#.
|
| Application |
| Suitable for direct burial, duct, and aerial installations (where supported by a messenger) where moisture protection is required.
|
| Standards |
| RUS: 7 CFR 1755.890
|
| (REA PE-89)
|
|
|