OUTSIDE PLANT TELEPHONE CABLE
FOAM-SKIN, FILLED, DIRECT BURIAL
RUS (REA) PE-89 #22 AND #19 AWG
| Construction: |
| CONDUCTOR: |
SOLID ANNEALED BARE COPPER.
|
| TWO-LAYER INSULATION: |
1) INNER LAYER OF FOAMED POLYOLEFIN.
|
| 2) OUTER SKIN OF SOLID COLOR CODED POLYOLEFIN.
|
| CORE ASSEMBLY: |
INSULATED CONDUCTORS ARE TWISTED INTO PAIRS OF VARYING TWIST LENGTHS TO MINIMIZE CROSSTALK.
|
| CABLES OF 25PAIRS OR LESS ARE ASSEMBLED INTO A SINGLE GROUP.
|
| CABLES OVER 25PAIRS ARE ARRANGED INTO SUBUNITS.
|
| A FLOODING COMPOUND IS APPLIED TO THE ENTIRE CORE ASSEMBLY, COMPLETELY FILLING THE AIR SPACE BETWEEN THE INSULATED CONDUCTORS AND ALSO UNDER THE NON-HYGROSCOPIC TAPE WHICH WRAPS THE CABLE CORE.
|
| SHIELD: |
.008"INCH(8 MIL) COATED CORRUGATED ALUMINUM TAPE APPLIED LONGITUDINALLY.
|
| OVERALL JACKET: |
BLACK POLYETHYLENE.
|
| Charlotte Wire Part#* ↓ |
Size AWG |
Number of Pairs |
Overall Diameter (in.) |
Approx. Net Wt. (Lbs/Mft) |
Add to Quote Cart |
| CW09791 |
22 |
6 |
.46" |
90 |
|
| CW09792 |
22 |
12 |
.55" |
138 |
|
| CW09793 |
22 |
25 |
.66" |
228 |
|
| CW09794 |
22 |
50 |
.86" |
390 |
|
| CW09795 |
22 |
100 |
1.12" |
710 |
|
| CW09796 |
22 |
200 |
1.47" |
1340 |
|
| CW09797 |
22 |
300 |
1.78" |
1940 |
|
| CW09798 |
22 |
400 |
2.03" |
2520 |
|
| CW09799 |
22 |
600 |
2.42" |
3750 |
|
| CW09800 |
22 |
900 |
2.91" |
5630 |
|
| CW09801 |
22 |
1200 |
3.50" |
7400 |
|
| CW09802 |
19 |
6 |
.54" |
140 |
|
| CW09803 |
19 |
12 |
.69" |
220 |
|
| CW09804 |
19 |
25 |
.85" |
390 |
|
| CW09805 |
19 |
50 |
1.12" |
700 |
|
| CW09806 |
19 |
100 |
1.52" |
1360 |
|
| Displaying 1 to 16 (of 16 products) |
Result Pages: 1 |
| * Note: To Specify alternate longitudinal shield to standard, add suffixes to CWC part# as follows:
|
| 1) for 5mil corrugated copper tape, add suffix "-CU" to CWC part#.
|
| 2) for 5-6mil corrugated copper clad steel or alloy gopher resistant tape, add suffix "-GO" to CWC part#.
|
| 3) for dual 8mil aluminum plus 6mil steel tape, add suffix "-ALS" to CWC part#.
|
| Application |
| Suitable for direct burial, duct, and aerial installations (where supported by a messenger) where moisture protection is required.
|
| Standards |
| RUS CFR 1755.890 (REA PE-89)
|
|
|