OUTSIDE PLANT TELEPHONE CABLE
SOLID INSULATION, FILLED, DIRECT BURIAL
RUS (REA) PE-39 SIZE #22 & #19AWG

Construction:
CONDUCTOR: SOLID ANNEALED BARE COPPER.
INSULATION: SOLID HIGH DENSITY POLYOLEFIN COLOR CODED PER INDUSTRY STANDARDS.
CORE ASSEMBLY: INSULATED CONDUCTORS ARE TWISTED INTO PAIRS OF
VARYING TWIST LENGTHS TO MINIMIZE CROSSTALK.
CABLES OF 25PAIRS OR LESS ARE ASSEMBLED INTO A SINGLE GROUP.
CABLES OVER 25PAIRS ARE ARRANGED INTO SUBUNITS.
A FLOODING COMPOUND IS APPLIED TO THE ENTIRE CORE ASSEMBLY, COMPLETELY FILLING THE AIR SPACE BETWEEN THE INSULATED CONDUCTORS AND ALSO UNDER THE NON-HYGROSCOPIC TAPE WHICH WRAPS THE CABLE CORE.
SHIELD: .008"INCH(8 MIL) COATED CORRUGATED ALUMINUM TAPE APPLIED LONGITUDINALLY.
OVERALL JACKET: BLACK POLYETHYLENE.
 Charlotte Wire Part# * ↓   Size AWG   Number of Pairs   Overall Diameter (in.)   Approx. Net Wt. (Lbs/Mft)   Add to Quote Cart 
CW09841 22 6 .46" 108 Request Quote For This Product 
CW09842 22 12 .58" 168 Request Quote For This Product 
CW09843 22 25 .76" 282 Request Quote For This Product 
CW09844 22 50 1.00" 510 Request Quote For This Product 
CW09845 22 100 1.30" 860 Request Quote For This Product 
CW09846 22 200 1.76" 1630 Request Quote For This Product 
CW09847 22 300 2.11" 2380 Request Quote For This Product 
CW09848 22 400 2.42" 3140 Request Quote For This Product 
CW09849 22 600 2.93" 4700 Request Quote For This Product 
CW09850 22 900 3.48" 6870 Request Quote For This Product 
CW09851 19 6 .65" 158 Request Quote For This Product 
CW09852 19 12 .80" 280 Request Quote For This Product 
CW09853 19 25 1.04" 500 Request Quote For This Product 
CW09854 19 50 1.36" 920 Request Quote For This Product 
CW09855 19 100 1.90" 1710 Request Quote For This Product 
Displaying 1 to 15 (of 15 products) Result Pages:  1 
* Note: To Specify alternate longitudinal shield to standard, add suffixes to CWC part# as follows:
1) for 5mil corrugated copper tape, add suffix "-CU" to CWC part#.
2) for 5-6mil corrugated copper clad steel or alloy gopher resistant tape, add suffix "-GO" to CWC part#.
3) for dual 8mil aluminum plus 6mil steel tape, add suffix "-ALS" to CWC part#.
Application
Suitable for direct burial, duct, and aerial installations (where supported by a messenger) where moisture protection is required.
Standards
RUS: 7 CFR 1755.390
(REA PE-39)